Allergic contact reactions due to phenylephrine hydrochloride in eyedrops.

Moreno-Ancillo A, Munoz-Robles M L, Cabañas R, Barranco P, Lopez-Serrano M C

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Dermatitis of and around the eye is common. Allergic contact reactions from phenylephrine are rare despite extensive use by ophthalmologists. Previous reports do not indicate crossreactivity between phenylephrine and other sympathomimetic drugs in patch testing.

METHODS

We report three cases of allergic contact reactions (dermato-conjunctivitis) after eyedrops. Skin prick tests, epicutaneous testing with the implicated drugs, additives, and a complete patch test battery, TRUE test (Upjohn-Pharmacia, Sweden), were performed in each patient.

RESULTS

All skin prick tests were negative. The three patients showed positive patch tests to phenylephrine and one of them also to ephedrine. Tolerance of the other eyedrops without phenylephrine was verified by challenge.

CONCLUSION

Phenylephrine was the responsible agent for the reactions in our patients as confirmed by clinical findings and positive patch tests. Our findings suggest the central structure as the sensitizing part of drug in the second patient. Patch testing is essential for diagnosis of allergic contact reactions of and around the eye.

Для цитирования: Moreno-Ancillo A, Munoz-Robles M L, Cabañas R, Barranco P, Lopez-Serrano M C. Allergic contact reactions due to phenylephrine hydrochloride in eyedrops.. Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology. 1997. DOI: 10.1016/s1081-1206(10)63217-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.