Hemodynamic evolution of heart failure from hypertension: lower stroke volume index and higher heart rate.
Аннотация
BACKGROUND
There is little information about systemic hemodynamic changes in the evolution of heart failure (HF) from hypertension.
METHODS
We compared 24-hour mean hemodynamic variables derived from ambulatory pulse wave analysis (Mobil-O-Graph) in at-risk patients with hypertension (Stage A/B HF) and patients with Stage C HF secondarily stratified by ejection fraction (EF: low <40% or high ≥40%).
RESULTS
Differences (mean ± SEM) between Stage A/B (n = 109) and Stage C HF (n = 52) were, respectively: stroke volume index (SVI) 36.8 vs. 31.9 mL/m2 (P < .001), heart rate (HR) 68.1 vs. 76.4 bpm (P < .001), and arterial stiffness (pulse pressure/SVI) 1.47 vs. 1.65 mmHg/mL/m2 (P < .05); cardiac index and total vascular resistance index did not differ between groups. Robust inverse correlations between SVI and HR were found in both Stage A/B and Stage C HF (P < .001); each 10 beat/min change in HR was accompanied by a reciprocal SVI change of 3 mL/m2; overall, SVI was 5%-10% lower in Stage C compared to Stage A/B HF. Hemodynamic profiles, especially high HR and low SVI, were quantitatively similar in Stage C HF patients with low or high EF. Low SVI (<35 mL/min/m2) conferred a specificity for Stage C HF of 71%; adding high HR (>75 bpm) increased specificity to 84%.
CONCLUSIONS
Ambulatory hemodynamic monitoring is feasible in HF patients; low 24-hour SVI and high HR are highly correlated and together can differentiate Stage C from Stage A/B HF, irrespective of EF. Further study of hemodynamic profiles in HF staging and prognosis is warranted.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.