m+Medelevator.RU
← Поиск публикаций
Head & face medicine · 2026

Long-term stability of ocular function after alloplastic computer-aided design/computer-aided manufacturing reconstruction of posttraumatic orbital defects: a retrospective cohort study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Skade S, Linderkamp M L, Lentge F, Korn P, Jehn P, Gellrich N C, Hufendiek K, Zimmerer R, Neuhaus M T

Аннотация

BACKGROUND: We investigated the long-term stability of ocular function and eyeball position after posttraumatic orbital reconstruction of patient-specific implants using alloplastic computer-aided design/computer-aided manufacturing (CAD/CAM). In this study, we evaluated the extent to which precise anatomical reconstruction contributes to stable functional and aesthetic outcomes over time. METHODS: Between 2010 and 2018, we retrospectively analyzed 69 patients who underwent orbital floor and medial wall reconstruction. The patients were classified into two groups following the implant type: CAD/CAM-manufactured titanium implants and standard CAD-based titanium implants. Long-term follow-up (LTFU) assessments included globe positioning, diplopia, motility, visual acuity, and intraocular pressure. The differences between the two groups were determined using statistical analyses. RESULTS: Deviations in the sagittal and vertical globe positions persisted after a median follow-up of 56 months in both groups, with no significant differences. Vertical globe deviation is significantly associated with diplopia. Patients with CAD-based implants showed a higher tendency for motility restriction and lower visual acuity than those with CAD/CAM implants. Intraocular pressure was significantly lower in the affected eyes in both groups. CONCLUSION: CAD/CAM-designed implants provide improved anatomical reconstruction; however, they do not significantly improve long-term globe positioning than CAD-based implants. However, they may also contribute to improved motility and visual outcomes. A close interdisciplinary approach involving ophthalmologists is important for optimizing treatment planning and postoperative assessments.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты