MedElevator Войти в исследования
← Поиск публикаций

DOI 10.13107/jocr.2025.v15.i12.6474

Медицинская библиотека · Journal of orthopaedic case reports · 2025

Fractured Connection: Unmasking Primary Hyperparathyroidism through Bilateral Quadriceps Tendon Rupture - A Case Report.

Nazar I M Maqbal Muhasin, Mammu Sharafuddeen, Chacko V H Nidhin, Chandran Rahul, Rajamohanan Ashwin, Karinkappara Shaneed

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Bilateral spontaneous quadriceps tendon rupture (QTR) is extremely rare. This condition involves the simultaneous tear of the fibrous tissue connecting the quadriceps muscle to the patella bone. The importance of prompt diagnosis is emphasized, as early recognition is crucial for initiating appropriate treatment and achieving optimal outcomes.

CASE REPORT: This article presents a case report detailing the management of bilateral QTR alongside concomitant parathyroid adenoma in a 38-year-old male. The patient underwent open repair of both bilateral quadriceps tendons, followed by a well-planned physiotherapy protocol. Furthermore, surgical removal of the parathyroid adenoma was performed. A favourable functional outcome was observed during the 6-month follow-up period.

CONCLUSION

This case report highlights the critical aspects of managing bilateral spontaneous quadriceps rupture alongside concomitant parathyroid adenoma. Addressing the diagnostic and management challenges associated with this rare condition underscores the importance of early diagnosis, prompt surgical intervention, and tailored rehabilitation programs. This comprehensive approach contributes to the existing literature and emphasizes the significance of multidisciplinary collaboration in achieving favourable patient outcomes.

Для цитирования: Nazar I M Maqbal Muhasin, Mammu Sharafuddeen, Chacko V H Nidhin, Chandran Rahul, Rajamohanan Ashwin, Karinkappara Shaneed. Fractured Connection: Unmasking Primary Hyperparathyroidism through Bilateral Quadriceps Tendon Rupture - A Case Report.. Journal of orthopaedic case reports. 2025. DOI: 10.13107/jocr.2025.v15.i12.6474.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.