MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15266028251324074

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2025

Use of the Electrified Wire Technique for In Situ Fenestration Creation Within a Branch Bridging Stent.

Giordano Antonino, Nana Petroula, Panuccio Giuseppe, Arulrajah Kugarajah, Torrealba José I, Rohlffs Fiona, Kölbel Tilo

СтатьяКлинический случайПеревод в очереди

Аннотация

PURPOSE: To present the use of the electrified wire technique as bailout for target vessel (TV) branch preservation after unintended coverage by a bridging stent during branched endovascular repair (bEVAR).

TECHNIQUE: A 73-year-old male, previously treated with thoracic endovascular aortic repair and Provisional Extension to Induce Complete Attachment Technique (PETTICOAT) for type B aortic dissection, presented with a 68 mm type V thoracoabdominal aortic aneurysm. The patient presented an anatomic variation with a common trunk for the superior mesenteric artery (SMA) and celiac artery (CA). After a previously failed open surgical attempt, a triple-branch custom-made device (2 renal branches and 1 for the SMA/CA trunk) was chosen. Endograft deployment and TV catheterization were uneventful, until an unintended coverage of the CA occurred, due to bridging stent unmount. Using the electrified wire technique, an in situ fenestration was created into the CA/SMA trunk covered bridging stent to preserve CA patency. A bare metal stent was used for CA revascularization. Renal arteries were catheterized and bridged as planned. The 6-month computed tomography angiography confirmed TV patency.

CONCLUSION

The electrified wire technique may be used as bailout for in situ fenestration creation in unintended coverage of early TV side-branches.Clinical ImpactAnatomic variations may increase the technical complexity of branched endovascular aortic repair while technical pitfalls related to target vessel preservation may demand the application of bailout techniques. In this case, the electrified wire technique was used to create an in situ fenestration within the bridging stent of a celiac artery (CA) and superior mesenteric artery common trunk (anatomic variation), after bridging stent unmount during advancement and CA unintended coverage.

Для цитирования: Giordano Antonino, Nana Petroula, Panuccio Giuseppe, Arulrajah Kugarajah, Torrealba José I, Rohlffs Fiona, Kölbel Tilo. Use of the Electrified Wire Technique for In Situ Fenestration Creation Within a Branch Bridging Stent.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2025. DOI: 10.1177/15266028251324074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.