MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000442749

Медицинская библиотека · International archives of allergy and immunology · 2016

Serum Biomarkers of Allergic Contact Dermatitis: A Pilot Study.

Zinkevičienė Auksė, Kainov Denis, Lastauskienė Eglė, Kvedarienė Violeta, Bychkov Dmitrii, Byrne Myles, Girkontaitė Irutė

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Allergic contact dermatitis (ACD) is an inflammatory skin disease caused by repeated skin exposure to contact allergens. The goal of this pilot study was to identify inflammatory proteins which can serve as biomarkers for ACD.

METHODS

We measured levels of 102 cytokines, chemokines, and growth factors in the sera of 16 ACD patients during acute and remission phases, and 16 healthy volunteers.

RESULTS

Serum levels of adiponectin, chemokine (C-C motif) ligand 5 (CCL5), C-reactive protein (CRP), chitinase 3-like 1 (CHI3L1), complement factor D (CFD), endoglin, lipocalin-2, osteopontin, retinol-binding protein 4 (RBP4), and platelet factor 4 (PF4) were significantly higher, whereas levels of trefoil factor 3 (TFF3) were significantly lower, in ACD patients than in healthy controls. In ACD patients, serum levels of CCL5 were elevated, whereas levels of TFF3, soluble intercellular adhesion molecule-1 (sICAM-1), and platelet-derived growth factor (PDGF)-AB/BB were found to be lower during the remission phase of the disease.

CONCLUSIONS

Serum levels of adiponectin, CCL5, CRP, CHI3L1, CFD, endoglin, lipocalin-2, osteopontin, RBP4, PF4, and TFF3 might be exploited as biomarkers for ACD, whereas levels of CCL5, TFF3, sICAM-1, and PDGF-AB/BB might be exploited for evaluation of disease progression and efficacy of ACD treatment.

Для цитирования: Zinkevičienė Auksė, Kainov Denis, Lastauskienė Eglė, Kvedarienė Violeta, Bychkov Dmitrii, Byrne Myles, Girkontaitė Irutė. Serum Biomarkers of Allergic Contact Dermatitis: A Pilot Study.. International archives of allergy and immunology. 2016. DOI: 10.1159/000442749.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.