Lactose Breath Test: Possible Strategies to Optimize Test Performance, Accuracy, and Clinical Impact.
Аннотация
Lactose malabsorption (LM) refers to the incomplete absorption of lactose in the small intestine, resulting in the arrival of ingested lactose in the colon, which can give rise to symptoms defined as lactose intolerance (LI). The lactose breath test (LBT), thanks to its low cost, availability, and noninvasiveness, is the most used diagnostic method. However, the LBT is a tedious tool, requiring prolonged involvement of patients, qualified staff, and infrastructure, of which the most time-consuming factor is the frequency and number of breath samples needed.
Objectives
To simplify the current LBT methodology, compliant with the current guidelines' statements, by reducing the test duration or the number of breath samples, without compromising the test's accuracy.
Methods
The results of the standard LBT were compared with two simplified tests: a "shortened" test, lasting three hours, with samples taken every 30 min; and a "five-sample" test, lasting four hours, with samples taken every hour. Patients were stratified into three grades of malabsorption (mild, moderate, severe) based on the amount of gas exhaled. A clinical severity score was introduced to assess the clinical relevance of LI using a specific questionnaire.
Results
Among the 543 patients enrolled (F 71.5%, mean age 43.7 ± 17.6 yrs), 60.4% (328/543) tested positive for LM. A total of 70.5% (383/543) presented LI, with 32.1% of those being true intolerants (LI without LM). The shortened test demonstrated an accuracy of 93.9%, with a sensitivity of 89.9% and a false negative rate of 10.1% (33/328). The five-sample test showed higher accuracy and sensitivity than the shortened test (96.5% and 94.2%, respectively; p = 0.03) with a false negative rate of 5.8% (19/328). Of the 19 false negatives in the five-sample test, 95% (18/19) were categorized as mild malabsorbents. No statistical correlation was found between the clinical severity score and LBT results.
Conclusions
The five-sample test, involving hourly breath measurements, is a reliable option for simplifying the LBT without significantly reducing the procedure's sensitivity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.