MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo-2023-323308

Медицинская библиотека · The British journal of ophthalmology · 2024

Detecting the corneal neovascularisation area using artificial intelligence.

Mergen Burak, Safi Tarek, Nadig Matthias, Bhattrai Gopal, Daas Loay, Alexandersson Jan, Seitz Berthold

СтатьяПеревод в очереди

Аннотация

AIMS: To create and assess the performance of an artificial intelligence-based image analysis tool for the measurement and quantification of the corneal neovascularisation (CoNV) area.

METHODS

Slit lamp images of patients with CoNV were exported from the electronic medical records and included in the study. An experienced ophthalmologist made manual annotations of the CoNV areas, which were then used to create, train and evaluate an automated image analysis tool that uses deep learning to segment and detect CoNV areas. A pretrained neural network (U-Net) was used and fine-tuned on the annotated images. Sixfold cross-validation was used to evaluate the performance of the algorithm on each subset of 20 images. The main metric for our evaluation was intersection over union (IoU).

RESULTS

The slit lamp images of 120 eyes of 120 patients with CoNV were included in the analysis. Detections of the total corneal area achieved IoU between 90.0% and 95.5% in each fold and those of the non-vascularised area achieved IoU between 76.6% and 82.2%. The specificity for the detection was between 96.4% and 98.6% for the total corneal area and 96.6% and 98.0% for the non-vascularised area.

CONCLUSION

The proposed algorithm showed a high accuracy compared with the measurement made by an ophthalmologist. The study suggests that an automated tool using artificial intelligence may be used for the calculation of the CoNV area from the slit-lamp images of patients with CoNV.

Для цитирования: Mergen Burak, Safi Tarek, Nadig Matthias, Bhattrai Gopal, Daas Loay, Alexandersson Jan, Seitz Berthold. Detecting the corneal neovascularisation area using artificial intelligence.. The British journal of ophthalmology. 2024. DOI: 10.1136/bjo-2023-323308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.