The effect of annular repair on the failure strength of the porcine lumbar disc after needle puncture and punch injury.

Yang Chih-Hong, Chiang Yueh-Feng, Chen Chia-Hsien, Wu Lien-Chen, Liao Chun-Jen, Chiang Chang-Jung

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose was to quantify the structural integrity of annulus fibrosis (AF) after injuries with repair.

METHODS

Punctures in the AF of 6-month-old porcine spine specimens were made with 18-, 20-, 22-, 24-, and 26-gauge needles. Leakage testing was performed immediately after needle puncture (Group 1), after the puncture was repaired with a modified purse-string suture (MPSS) (Group 2), and after needle puncture with immediate repair (Group 3). Punch injuries repaired with the MPSS alone, or with an AF graft and MPSS were also examined.

RESULTS

There was no leakage from 26-gauge needle punctures. Pressures at which the nucleus pulposus leaked from the 24-, 22-, 20- and 18-gauge needle punctures (Group 1) were 4.28, 2.03, 1.27, and 1.06 MPa, respectively. Failure pressure after repair (Group 2, 3) was significantly greater than without (Group 1). Failure pressure in Group 3 was much greater than in Group 2 with 18- and 20-gauge punctures. Punch injury repaired with a graft and MPSS had significantly greater failure pressure than repair with MPSS alone (1.88 vs. 1.02 MPa, p = 0.0001).

CONCLUSIONS

The MPSS can restore the mechanical integrity of the AF after needle puncture. An annular graft along with a MPSS may increase the structural integrity of the AF after a punch injury. As this was an acute animal study, the measurements and results may not directly translate to the human intervertebral disc.

Для цитирования: Yang Chih-Hong, Chiang Yueh-Feng, Chen Chia-Hsien, Wu Lien-Chen, Liao Chun-Jen, Chiang Chang-Jung. The effect of annular repair on the failure strength of the porcine lumbar disc after needle puncture and punch injury.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2015. DOI: 10.1007/s00586-015-4316-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.