MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09273948.2025.2555615

Медицинская библиотека · Ocular immunology and inflammation · 2025

Anterior Segment Optical Coherence Tomography in Endophthalmitis.

Mautone Luca, Ponti Laura, Sanchis Pierre, Druchkiv Vasyl, Skevas Christos, Birtel Johannes, Spitzer Martin S

СтатьяПеревод в очереди

Аннотация

PURPOSE: Anterior Segment Optical Coherence Tomography (AS-OCT) can assess anterior chamber's (AC) changes. This study aims to describe AC changes in eyes with endophthalmitis using AS-OCT.

METHODS

Electronic patient records, slit lamp photography and anterior segment infrared imaging were reviewed in this retrospective single-center cohort study and correlated to swept-source AS-OCT scans of eyes with endophthalmitis.

RESULTS

Fourteen eyes of 14 patients with postoperative (n = 6 after cataract surgery; n = 6 after anti-VGEF-injection) and endogenous (n = 2) endophthalmitis were included. The visual acuity was light perception (n = 3), hand movement (n = 7) and ≥1.30 LogMar (n = 4). On slit lamp examination, hypopyon (n = 13) and fibrin (n = 5) were seen. AS-OCT detected hypopyon (n = 13) and fibrin formations (n = 10); hypopyon appeared as a hyperreflective level at the bottom of the AC and showed a hyperreflective lamellar prolongation on the corneal endothelium. Fibrin had the shape of hyperreflective filaments and presented in four patterns: single-stranded, stork-nest-like, cloth-like, or with a mixed phenotype.

CONCLUSION

AS-OCT imaging may visualize inflammatory activity of the AC in endophthalmitis and enable a morphological characterization of fibrin formation. Characteristic findings are also seen in cases with reduced corneal transparency.

Для цитирования: Mautone Luca, Ponti Laura, Sanchis Pierre, Druchkiv Vasyl, Skevas Christos, Birtel Johannes, Spitzer Martin S. Anterior Segment Optical Coherence Tomography in Endophthalmitis.. Ocular immunology and inflammation. 2025. DOI: 10.1080/09273948.2025.2555615.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.