m+Medelevator.RU
← Поиск публикаций
Clinica chimica acta; international journal of clinical chemistry · 2022

Defects and countermeasures in laboratory diagnosis of rare IgE multiple myeloma.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Yongjian, Chen Yuzhou, Zhou Yanping, Zho FeiFei, Wang Sumei, Zheng Sujie, Shen Yuhuan, Tong Xiangmin, Du Jing, Li Yanchun

Аннотация

BACKGROUND: IgE multiple myeloma (MM) is a rare subtype of MM that is easily misdiagnosed. We report a rare case of IgE-MM and investigate the application of the SLiM-CRAB criteria to screen for high-risk smoldering MM (SMM) patients, so as to summarize the causes and methods used to prevent missed diagnosis or misdiagnosis in IgE-MM.

METHODS: The serum monoclonal protein (M-protein) classification and IgE quantification was performed and sent to several individual institutions. The results were collected and the causes of IgE detection defects were analyzed.

RESULTS: Upon admission to our hospital, the patient's serum free kappa light chain was 1069.9 mg/L, free lambda light chain was 9.2 mg/L, and free kappa/lambda ratio was 115.9, which met the SLiM criteria, but without CRAB features. Immunofixation electrophoresis (IF) showed "M-like protein aggregation bands" in all lanes. After pretreatment with 1% β-mercaptoethanol to depolymerize the aggregation of monoclonal protein, the "M-like protein aggregation bands disappeared. The other five institutions did not provide the correct typing results. The quantification of serum IgE was as high as 2.06 × 107 IU/mL, whereas 7 other testing institutions reported IgE levels ranging from 1.0 to 1100 IU/mL.

CONCLUSION: High-risk biomarkers in SLiM criteria can achieve good therapeutic effects in rare IgE-MM patients. Serum immunofixation performed without antisera against IgE, insufficient identification of the lytic bands produced by high macromolecule aggregation in IF, and the absence of a prozone effect avoidance procedure during IgE quantitative detection are the primary causes of missed diagnosis or misdiagnosis in patients with IgE-MM.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты