MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/03009742.2026.2644006

Медицинская библиотека · Scandinavian journal of rheumatology · 2026

Does lacrimal gland ultrasound discriminate between Sjögren's disease and non-Sjögren's sicca patients?

Sluijpers Nrf, Yang T, Stel A J, van Nimwegen J F, Olie L, Vehof J, van der Geest Ksm, Bootsma H, Arends S, Coumou A D, Pringle S, Delli K

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the performance of colour Doppler lacrimal gland ultrasound (LGUS CD) for discriminating Sjögren's disease (SjD) from non-SjD sicca patients under routine clinical practice conditions.

METHOD: Forty patients with clinically suspected SjD underwent ocular function tests [Schirmer's test, ocular staining score (OSS)] and LGUS CD evaluation. Ultrasound images and videos were scored for both lacrimal glands using the Outcome Measures in Rheumatology (OMERACT) CD scoring system (range 0-3). Subsequently, a total score (range 0-6) was calculated for each patient. Sensitivity and specificity of LGUS CD and ocular function tests were calculated to predict SjD classification according to 2016 American College of Rheumatology/European Alliance of Associations for Rheumatology (ACR/EULAR) classification criteria. Construct validity of LGUS CD was assessed by determining Spearman's correlation coefficients between LGUS CD, Schirmer's test, and OSS.

RESULTS

Twenty-three patients were classified with SjD and 17 as non-SjD sicca patients. LGUS CD sensitivity was 57% and specificity was 53% for prediction of classification according to 2016 ACR/EULAR classification criteria for SjD. Total LGUS CD score of both eyes and the individual LGUS CD score of the left and right eye did not differ significantly between SjD and non-SjD sicca patients. None of the ACR/EULAR classification criteria differed significantly between the groups with high and low LGUS CD scores. Poor correlations were determined between LGUS CD and ocular function tests (ρ = 0.028-0.187).

CONCLUSION

LGUS CD demonstrated similar characteristics in SjD and non-SjD sicca patients, suggesting limited discriminatory value. Refined ultrasonographic scoring systems are needed to improve differentiation between these patient groups.

Для цитирования: Sluijpers Nrf, Yang T, Stel A J, van Nimwegen J F, Olie L, Vehof J, van der Geest Ksm, Bootsma H, Arends S, Coumou A D, Pringle S, Delli K. Does lacrimal gland ultrasound discriminate between Sjögren's disease and non-Sjögren's sicca patients?. Scandinavian journal of rheumatology. 2026. DOI: 10.1080/03009742.2026.2644006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.