Ultrasound-measured optic nerve sheath diameter as a non-invasive tool for screening elevated-pressure from normal-pressure hydrocephalus: a cross-sectional study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wen Jianhuan, Zhang Lu, Yang Xing, Mo Yixiang, Zhang Shizhong, Zhang Yu, Zeng Yuqing, Gao Lijie, Guo Yanwu, Xie Tao

Аннотация

This study evaluates the diagnostic accuracy of ultrasound-measured optic nerve sheath diameter (US-ONSD) in distinguishing elevated-pressure hydrocephalus from normal-pressure hydrocephalus (NP-HCP), with the aim of establishing clinically relevant ONSD thresholds for screening and confirming elevated intracranial pressure (ICP) in clinical practice. This cross-sectional study, conducted at the Neurosurgery Center of Zhujiang Hospital, included patients diagnosed with hydrocephalus. Standardized US-ONSD measurements were performed on all participants, followed by lumbar puncture (LP) to measure ICP. The diagnostic accuracy of US-ONSD measurements was evaluated using receiver operating characteristic (ROC) curve analysis, focusing on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A 2 × 2 contingency table was used to determine the optimal ONSD thresholds for screening and confirming elevated ICP. A total of 42 hydrocephalus patients were included in this study: 22 patients with elevated-pressure hydrocephalus and 20 with normal-pressure hydrocephalus. The mean ONSD was significantly higher in the elevated-pressure group compared to the normal-pressure group (5.60 mm vs. 4.70 mm, p < 0.001). The overall cohort had a mean age of 53.6 years (SD 15.7), with 20 males (47.6%). The average weight, height, and body mass index (BMI) were 59.0 kg (SD 9.8), 163.2 cm (SD 7.3), and 22.1 kg/m² (SD 3.2), respectively. Receiver operating characteristic (ROC) analysis demonstrated excellent diagnostic performance (AUC = 0.957, 95% CI: 0.888-1.000). The optimal ONSD thresholds for excluding elevated ICP were 4.82 mm (NPV = 1), and for confirming elevated ICP were 5.75 mm (PPV = 1), thereby maximizing sensitivity and specificity. US-ONSD is a reliable, non-invasive method for detecting elevated ICP in patients with hydrocephalus. We propose two ONSD threshold values for clinical application: 4.82 mm for excluding elevated ICP and 5.75 mm for confirming it. These thresholds provide a practical and effective approach for screening and confirming elevated ICP, particularly in scenarios where invasive procedures, such as lumbar puncture, are not feasible or are contraindicated. Further multi-center studies are needed to validate these thresholds and optimize their clinical utility.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты