MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/nmo.12802

Медицинская библиотека · Neurogastroenterology and motility · 2016

(13) C mannitol as a novel biomarker for measurement of intestinal permeability.

Grover M, Camilleri M, Hines J, Burton D, Ryks M, Wadhwa A, Sundt W, Dyer R, Singh R J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Gastrointestinal (GI) and non-GI disorders are associated with altered intestinal permeability, which can be measured in vivo by urinary excretion after oral lactulose and mannitol ingestion. Inadvertent dietary consumption of (12) Carbon ((12) C, regular) mannitol in food or from other sources may interfere with the test's interpretation. (13) Carbon ((13) C) constitutes 1% of carbon in nature and (13) C mannitol is a stable isotope. Our aim was to determine the performance of (13) C mannitol for measurement of intestinal permeability.

METHODS

Ten healthy volunteers underwent intestinal permeability assay using coadministered (12) C mannitol, (13) C mannitol and lactulose, followed by timed urine collections. Urinary sugar concentrations were measured using tandem high performance liquid chromatography-mass spectrometry.

KEY

RESULTS

We found that (13) C mannitol can be distinguishable from (12) C mannitol on tandem mass spectrometry. In addition, (13) C mannitol had ~20-fold lower baseline contamination compared to (12) C mannitol. We describe here the (13) C mannitol assay method for the measurement of intestinal permeability.

CONCLUSIONS & INFERENCES: In conclusion, (13) C mannitol is superior to (12) C mannitol for measurement of intestinal permeability. It avoids issues with baseline contamination and erratic excretions during the testing period.

Для цитирования: Grover M, Camilleri M, Hines J, Burton D, Ryks M, Wadhwa A, Sundt W, Dyer R, Singh R J. (13) C mannitol as a novel biomarker for measurement of intestinal permeability.. Neurogastroenterology and motility. 2016. DOI: 10.1111/nmo.12802.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.