Respiration; international review of thoracic diseases · 2014

Endobronchial ultrasound-guided transbronchial needle aspiration: patient satisfaction under light conscious sedation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jeyabalan Abiramy, Medford Andrew R L

Аннотация

BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an increasingly used mediastinal sampling technique. Many centres use conscious sedation in an ambulatory setting to optimise the flow of patients, save costs and shorten recovery time. The only EBUS-TBNA patient satisfaction study published so far used deep conscious sedation with propofol. To our knowledge, ours is the largest prospective study evaluating the experience of patients undergoing EBUS-TBNA using light conscious sedation without propofol.

OBJECTIVES: To evaluate the patient tolerability of EBUS-TBNA under mild conscious sedation.

METHODS: Eighty-two consecutive patients between January 2011 and November 2011 requiring EBUS-TBNA under light conscious sedation for either mediastinal staging of lung cancer or the diagnosis of suspected mediastinal disease due to malignancy or granulomatous disease were invited to complete a questionnaire after the intervention. The collection of data included the diagnostic yield, the number and size of nodes sampled and the dose of sedative medication administered.

RESULTS: The average dose of sedative agents administered was 59.4 μg fentanyl and 3.2 mg midazolam. The sensitivity of EBUS-TBNA for the cancer staging, cancer diagnosis and granulomatous disease cohorts was 90.0, 94.1 and 87.5%, respectively. The most commonly reported symptom was a cough in 65 (93%) patients. Of these patients, 46 (71%) described the severity as being mild. All but 9 patients (61/70 or 87%) stated that they would definitely or probably undergo a repeat EBUS-TBNA.

CONCLUSIONS: This single-centre UK study confirms that EBUS-TBNA under light conscious sedation is a well-tolerated procedure maintaining the expected diagnostic performance, with patients reporting a high degree of satisfaction with both the test and the information received beforehand.