DOI 10.7759/cureus.90493

Медицинская библиотека · Cureus · 2025

Bilateral Cystoid Macular Edema After Light Treatment With Light-Adjustable Lens.

Shakarchi Fatma, Bassett Evelyn, Cooley Ayorinde, Martin Curtis R, Brandenburg Traeson, Dien Isabelle, Ferreira Lisia B, Shelby Christopher, Coleman Wyche T, LoBue Stephen

Клинический случайСтатьяПеревод в очереди

Аннотация

Light-adjustable lenses (LALs) allow for visual acuity (VA) adjustment after cataract surgery, using ultraviolet (UV) light therapy. UV-induced cystoid macular edema (CME) is not well documented. We report the first case of bilateral CME after UV light therapy with LAL. An 81-year-old woman underwent uncomplicated staged bilateral cataract extraction with LAL implantation. Two days after the second UV light adjustment, she had bilateral decreased VA and a new-onset bilateral CME. UV treatments were halted, and she was started on topical nonsteroidal anti-inflammatory drug (NSAID) therapy and prednisolone. CME completely resolved within three weeks following onset. Topical NSAID and prednisone drops were continued until the completion of all light treatments, followed by a slow taper over one month. We hypothesize that UV light can contribute to CME via multiple mechanisms, including UV-activated macromer byproducts, direct UV-induced injury, or ultraviolet B (UVB) disrupting the blood-aqueous barrier. Clinicians should be aware of this complication and maintain a low threshold for deferring light therapy and initiating topical treatment.

Для цитирования: Shakarchi Fatma, Bassett Evelyn, Cooley Ayorinde, Martin Curtis R, Brandenburg Traeson, Dien Isabelle, Ferreira Lisia B, Shelby Christopher, Coleman Wyche T, LoBue Stephen. Bilateral Cystoid Macular Edema After Light Treatment With Light-Adjustable Lens.. Cureus. 2025. DOI: 10.7759/cureus.90493.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.