m+Medelevator.RU
← Поиск публикаций
Reproductive biomedicine online · 2023

Comparison of clinical and ultrasound examinations in assessing the parametria in patients with deep infiltrating endometriosis: a multicentre prospective study.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Moro Francesca, Ianieri Manuel Maria, De Cicco Nardone Alessandra, Carfagna Pietro, Mascilini Floriana, Vizzielli Giuseppe, Biasioli Anna, Pontrelli Giovanni, Virgilio Bruna Anna, Ladisa Irene, Carlea Annunziata, Lo Turco Alice, Beneduce Giuliana, Arcieri Martina, Scaglione Giulia, Fanfani Francesco, Scambia Giovanni, Testa Antonia Carla

Аннотация

RESEARCH QUESTION: How do clinical rectovaginal examination and transvaginal ultrasound examination perform in the diagnosis of parametrial infiltration in patients with endometriosis?

DESIGN: This was a multicentre prospective observational study. Patients with suspected deep endometriosis at clinical examination and/or at ultrasound evaluation and scheduled for surgery were included. Following multicentre multidisciplinary meetings, consensus was obtained on terms and methodology to define the parametrium at pelvic anatomy, ultrasound and surgery. Sensitivity, specificity, accuracy, and positive and negative likelihood ratios were calculated for clinical and ultrasound examinations with respect to surgery.

RESULTS: In total, 195 women were selected for the present study and 164 were included in the analysis. Ultrasound examination had good to high specificity (>80%) for all parameters, except the left lateral parametrium (78.8%). The sensitivity of ultrasound examination was good to high for fixity of the right and left ovaries, uterosacral ligaments, retrocervix and rectovaginal space; and low for the anterior and lateral parametria, vagina, bladder and bowel. Clinical examination had good to high specificity for fixity of the left ovary, anterior parametrium, right uterosacral ligament, retrocervix and vagina; and low specificity for fixity of the right ovary, lateral parametrium, left uterosacral ligament and rectovaginal space. The sensitivity of clinical examination was good for the uterosacral ligaments and rectovaginal space, and low for the remaining parameters.

CONCLUSION: Ultrasound examination provided good specificity for all the parameters, but sensitivity was low for the anterior and lateral parametria. Clinical examination provided good specificity for the anterior and posterior parametria, but sensitivity was low for the anterior and lateral parametria. Further prospective studies are needed to validate this methodology and confirm the results.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты