MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0349878

Медицинская библиотека · PloS one · 2026

Combined diagnostic accuracy of two artificial intelligence systems for glaucoma diagnosis using color fundus photography.

da Silva Filho Gilvan Vilarinho, Caiado Gustavo Coelho, Yamamoto Felipe Zocatelli, Teixeira Sergio Henrique, Prata Tiago Dos Santos, Gracitelli Carolina Pelegrini Barbosa, Paranhos Augusto

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic accuracy of two commercially available artificial intelligence (AI) systems based on color fundus photography (CFP), the Laguna ONhE and VUNO Med-Fundus AI, for glaucoma detection, both independently and in combination.

METHODS

This retrospective cross-sectional study included 370 eyes from 193 patients (248 eyes with primary open-angle glaucoma and 122 healthy eyes). All eyes underwent structural evaluation with swept-source optical coherence tomography (Triton, Topcon) and visual field testing (Octopus 900, Haag-Streit AG). Fundus photographs were analyzed using Laguna ONhE and VUNO Med-Fundus AI systems. Diagnostic accuracy was evaluated.

RESULTS

Both AI systems demonstrated high diagnostic accuracy. Laguna achieved an AUC of 0.879 using Glaucoma Discriminant Function (GDF), and VUNO showed an AUC of 0.857. When combined, GDF + VUNO achieved an AUC of 0.903. The Global Mean Deviation (GMD) reached the highest diagnostic accuracy (AUC = 0.916), which was not significantly different from GDF + VUNO (p = 0.146).

CONCLUSIONS

Laguna ONhE and VUNO Med-Fundus AI had high diagnostic accuracy in detecting glaucoma using only CFP. Their combined use improved further, achieving accuracy comparable to the GMD. This represents a practical approach for glaucoma screening, particularly in settings without access to OCT or automated perimetry.

Для цитирования: da Silva Filho Gilvan Vilarinho, Caiado Gustavo Coelho, Yamamoto Felipe Zocatelli, Teixeira Sergio Henrique, Prata Tiago Dos Santos, Gracitelli Carolina Pelegrini Barbosa, Paranhos Augusto. Combined diagnostic accuracy of two artificial intelligence systems for glaucoma diagnosis using color fundus photography.. PloS one. 2026. DOI: 10.1371/journal.pone.0349878.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.