MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.12681

Медицинская библиотека · Contact dermatitis · 2016

Snapshot of cobalt, chromium and nickel exposure in dental technicians.

Kettelarij Jolinde, Nilsson Sara, Midander Klara, Lidén Carola, Julander Anneli

СтатьяПеревод в очереди

Аннотация

BACKGROUND

It is not fully understood where and how people are exposed to sensitizing metals. Much can be learnt from studying occupational settings where metals are handled.

OBJECTIVES

To quantify cobalt (Co), chromium (Cr) and nickel (Ni) exposure on the skin and in the air, and urine levels, in dental technicians working with tools and alloys that may result in skin and respiratory exposure.

METHODS

The metal skin dose was quantified with acid wipe sampling in dental technicians (n = 13). Air exposure was monitored by personal air sampling. Spot urine samples were collected for 24 h. Metals were analysed with inductively coupled plasma mass spectrometry.

RESULTS

Before work, Co was detected on the skin of 10 participants (0.00025-0.0039 µg/cm2 ), and Cr (0.00051-0.011 µg/cm2 ) and Ni (0.0062-0.15 µg/cm2 ) on the skin of all participants. After a 2-h period without hand washing, CoCr-exposed participants had more Co on the skin (p = 0.004) than non-CoCr-exposed participants. Co was found in 10 air samples (0.22-155 µg/m3 ), Cr in nine (0.43-71 µg/m3 ), and Ni in four (0.48-3.7 µg/m3 ). Metal urine concentrations were considered to be normal.

CONCLUSIONS

Dental technicians were exposed to Co, Cr and Ni on the skin and through the air, which was not reflected in the urine concentrations in this study. Cobalt skin doses may potentially elicit allergic contact dermatitis and cause sensitization.

Для цитирования: Kettelarij Jolinde, Nilsson Sara, Midander Klara, Lidén Carola, Julander Anneli. Snapshot of cobalt, chromium and nickel exposure in dental technicians.. Contact dermatitis. 2016. DOI: 10.1111/cod.12681.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.