BACKGROUND

Recent changes in regulatory restrictions and social opposition to animal toxicology experiments have driven the need for reliable in vitro tests for predicting the skin sensitizing potentials of a wide variety of industrial chemicals. Previously, we developed the human cell line activation test (h-CLAT) as a cell-based assay to predict the skin sensitizing potential of chemicals, and showed the correspondence between the h-CLAT and the murine local lymph node assay results.

OBJECTIVES

This study was conducted to investigate the predictive performance of the h-CLAT for human skin sensitizing potential.

MATERIALS/

METHODS

We selected a total of 66 test chemicals with known human sensitizing potential, and tested all chemicals with the h-CLAT. We then evaluated the performance of the h-CLAT in predicting human sensitizing potential.

RESULTS AND

CONCLUSION

Forty-five of 51 tested sensitizers were positive in the h-CLAT, indicating relatively high sensitivity. Also, 10 of 15 non-sensitizers were correctly detected as negative. The overall agreement between human data and h-CLAT outcome was 83%. Furthermore, the h-CLAT could accurately predict the human sensitizing potential of 23 tested chemicals that were amines, heterocyclic compounds, or sulfur compounds. Our data indicate the utility of the h-CLAT for predicting the human skin sensitizing potential of a variety of chemicals.

Для цитирования: Nukada Yuko, Ashikaga Takao, Sakaguchi Hitoshi, Sono Sakiko, Mugita Nanae, Hirota Morihiko, Miyazawa Masaaki, Ito Yuichi, Sasa Hitoshi, Nishiyama Naohiro. Predictive performance for human skin sensitizing potential of the human cell line activation test (h-CLAT).. Contact dermatitis. 2011. DOI: 10.1111/j.1600-0536.2011.01952.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.