m+Medelevator.RU
← Поиск публикаций
Annals of gastroenterology · 2026

Safety and diagnostic accuracy of ultrasound-assisted percutaneous liver biopsy in pediatric patients: a retrospective single-center study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rogalidou Maria, Zellos Aglaia, Stefanaki Kalliopi, Patereli Amalia, Dimakou Konstantina, Galina Paraskevi, Oikonomopoulos David, Papadopoulou Alexandra

Аннотация

BACKGROUND: Liver biopsy remains essential for diagnosing and managing pediatric liver diseases, despite advances in noninvasive techniques. However, data on the current indications, diagnostic yield, and safety of ultrasound-assisted percutaneous liver biopsy in children are limited.

METHODS: We retrospectively analyzed 60 pediatric patients who underwent ultrasound-assisted percutaneous liver biopsy at Agia Sofia Children's Hospital between January 2018 and September 2025. Data collected included demographics, laboratory values, biopsy indications, histopathology and complications. Biopsies were performed under anesthesia using an 18-G Tru-Cut needle with real-time ultrasound guidance. Hemoglobin and hematocrit were measured pre-procedure and at 4 and 24 h post-procedure. Specimen adequacy was assessed by core length and number of complete portal tracts (CPTs).

RESULTS: The mean patient age was 8.6 years (range 1 month to 17 years), with weights from 2.9-65 kg. Indications included persistent hypertransaminasemia, cholestasis, autoimmune and metabolic liver disease, and post-transplant evaluation. Mean biopsy length was 1.12 cm (range 0.5-2 cm), with a mean of 11 CPTs (range 4-17). Histopathology revealed autoimmune hepatitis (AIH) in 38.3%, AIH with primary sclerosing cholangitis in 13.3% of patients with inflammatory bowel disease, and other diagnoses in the remainder. No major complications or postprocedural bleeding occurred. Hemoglobin and hematocrit remained stable, and all specimens were adequate for histologic assessment.

CONCLUSIONS: Ultrasound-assisted percutaneous liver biopsy with an 18-G needle is safe, and yields sufficient tissue for diagnosis in pediatric patients. It continues to be indispensable for the definitive diagnosis, staging, and management of diverse liver diseases in children.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты