m+Medelevator.RU
← Поиск публикаций
Abdominal radiology (New York) · 2026

Inter-reader agreement for the assessment of portal vein thrombosis on computed tomography.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Plaforet Vincent, Moga Lucile, Elkrief Laure, Rautou Pierre-Emmanuel, Ronot Maxime

Аннотация

BACKGROUND AND AIMS: To evaluate the inter-reader reliability of CT-based measurements of portal vein thrombosis (PVT) to support the development of standardized response criteria endorsed by the Vascular Liver Disease Group (VALDIG) group.

METHODS: In this retrospective bi-centric study, 44 patients with PVT who underwent contrast-enhanced CT (2020-2024) were included. Two independent abdominal radiologists evaluated thrombus characteristics using pre-specified standardized measurements on portal venous phase CT acquisition. For the analysis of the main PVT, quantitative continuous measurement included thrombus length, thickness, and remnant lumen assessment based on diameter (%RLdiam) and surface area (%RLsurf). Categorical classifications were derived using both three-tier and four-tier occlusion scales. Qualitative categorical assessments were performed for involvement of the right and left portal branches, splenic vein, and superior mesenteric vein. Inter-reader agreement was assessed using intraclass correlation coefficients (ICC), weighted and unweighted Cohen's kappa (κ), and Bland Altman plots.

RESULTS: Inter-reader agreement for thrombus thickness and length yielded ICC values of 0.92 and 0.84 respectively. Agreement was highest for diameter-based remnant lumen assessment (%RLdiam; ICC = 0.93), outperforming surface-based measurements (%RLsurf; ICC = 0.83). Bland Altman plots confirmed narrower limits of agreement for diameter-based metrics (±22%) compared with surface-based metrics (-32% to +40%). Categorical classification based on diameter showed substantial agreement (weighted κ = 0.71 and 0.78 for three- and four-tier systems, respectively). Semi-quantitative assessment demonstrated substantial concordance, particularly for the right portal branch (κ = 0.77) and superior mesenteric vein (κ = 0.72).

CONCLUSIONS: Diameter-based quantitative assessment of PVT on CT demonstrates higher inter-reader reproducibility than surface-based measurements. The three-tier diameter-based categorization achieved substantial agreement and aligns with current hepatology guidelines, supporting its applicability in clinical practice and research settings.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты