MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20260212-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026

Rotational Stability and Vault Outcomes of the EVO ICL Using Oblique Implanting Orientation Compared to Horizontal/Vertical Implanting Orientation.

Li Zishuo, Kong Hongyu, Yao Ye, Li Zhen, Tian Tian, Chang Shihao, Yan Yan, Zhou Xingtao, Niu Lingling, Yao Peijun

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate the outcomes of Implantable Collamer Lens (EVO ICL; STAAR Surgical) implantation using customized oblique implanting orientation, focusing on rotational stability, vault predictability, and refractive efficacy compared to horizontal and vertical implanting orientations.

METHODS

In this prospective case series, 219 eyes of 110 patients underwent customized EVO ICL implantation guided by ultrasound biomicroscopy (UBM) measurements of sulcus-tosulcus (STS) diameters, ciliary sulcus morphology (MCS), and routine measurement of anterior segment including anterior chamber depth (ACD). Eyes were stratified into horizontal (n = 95), vertical (n = 41), and oblique (n = 83) groups based on implanting orientation. Postoperative assessments at 1 day, 1 week, 1 month, 3 months, and 1 year included refractive outcomes, vault measurements, and rotational degree analysis using slit-lamp photography and Mediview software.

RESULTS

At 1 year, all groups maintained ideal vault ranging from 118 to 1,053 µm, with 93.8% of eyes achieving 250 to 1,000 µm. The oblique group exhibited comparable vault (562.0 ± 189.2 µm) to the horizontal (571.2 ± 206.9 µm) and vertical (533.1 ± 185.4 µm) groups, with no significant intergroup differences (P = .64). Rotational stability showed no statistical differences among groups (oblique: 3.56 ± 2.78°, horizontal: 3.42 ± 2.49°, vertical: 3.24 ± 2.74°; P = .86). The most significant ICL rotation occurred within the initial postoperative week in all groups, with subsequent stabilization observed thereafter. Haptic positioning behind the ciliary processes correlated with reduced rotation (r = -0.37, P = .004) in the oblique group. Refractive outcomes were consistent across groups, with uncorrected distance visual acuity in 96.7% of eyes achieving preoperative corrected distance visual acuity and 85.5% of eyes having astigmatism of -0.50 diopters or less.

CONCLUSIONS

UBM-guided customized oblique implantation of an ICL achieved safety, efficacy, and vault predictability comparable to traditional implanting orientations, with good rotational stability, offering an alternative design to achieve optimal vault. Long-term rotational stability requires further observation.

Для цитирования: Li Zishuo, Kong Hongyu, Yao Ye, Li Zhen, Tian Tian, Chang Shihao, Yan Yan, Zhou Xingtao, Niu Lingling, Yao Peijun. Rotational Stability and Vault Outcomes of the EVO ICL Using Oblique Implanting Orientation Compared to Horizontal/Vertical Implanting Orientation.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2026. DOI: 10.3928/1081597x-20260212-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.