Normative values for high voltage electrical stimulation across the brachial plexus.
Аннотация
OBJECTIVES
To obtain normative values for High Voltage Electrical Stimulation across the brachial plexus between Erb's point, C8 root and T1 root. A case study of probable true thoracic outlet syndrome is used to illustrate the usefulness of the method.
METHODS
22 patients were tested for use in normative date pool with complaints unrelated to the ulnar nerve, the majority of which were pure carpal tunnel syndrome. High voltage stimulation was performed at Erb's point, C8 root and T1 root. Recording was from the abductor digit minimi muscle.
RESULTS
Upper limit for absolute latencies were 13.9 ms, 14.5 ms and 14.5 ms for Erb's point, C8 root and T1 root stimulation respectively. Corresponding lower limits of amplitude were 4.8 mV, 3.4 mV and 2.9 mV. Upper limits for interpeak latencies were 1.4 ms and 1.2 ms for C8 to Erb's point and T1 to Erb's point respectively. In a case of true thoracic outlet syndrome, the symptomatic side revealed prolonged interpeak and absolute latencies. The asymptomatic side remained within normal limits.
CONCLUSION
Normative values for high voltage stimulation across the brachial plexus are useful in cases of suspected compression in this proximal location of the upper limb.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.