DOI 10.1186/s44215-025-00234-1
Orthotopic heart transplantation for Fontan failure: experience and treatment strategy-a case report.
Аннотация
BACKGROUND
Orthotopic heart transplantation after the Fontan operation presents technical surgical challenges due to the connection of systemic veins to pulmonary arteries and well-developed systemic-to-pulmonary collateral arteries. The altered anatomy and hemodynamics necessitate extensive vascular reconstruction. We report a successful orthotopic heart transplantation with three years of ventricular assist device (VAD) support in a child who had undergone the Fontan operation.
CASE PRESENTATION: A 10-year-old boy had undergone extracardiac total cavopulmonary connection (18 mm expanded polytetrafluoroethylene conduit) at 2 years of age for a large ventricular septal defect, straddling tricuspid valve, and mitral stenosis. Following the Fontan operation, his systemic ventricular function gradually deteriorated. At 7 years of age, a Berlin Heart EXCOR® Pediatric VAD was implanted due to progressive heart failure, and he was listed for heart transplantation. Three years later, a heart transplant was performed. Cardiopulmonary bypass was established via cervical cannulation before re-sternotomy. The superior vena cava and extracardiac conduit were detached from the pulmonary artery. The pulmonary artery was reconstructed from hilum to hilum with a large bovine pericardial patch. Well-developed systemic-to-pulmonary collaterals caused excessive left atrial return; therefore, the left atrial anastomosis was performed under deep hypothermic circulatory arrest. The systemic veins were reconstructed with bicaval anastomosis, and inferior vena caval continuity was restored by leaving a short segment of the previous conduit. The procedure was completed without complications. Postoperative recovery was uneventful, and the patient was discharged on day 35.
CONCLUSIONS
This case illustrates a successful approach to orthotopic heart transplantation in a child with failing Fontan circulation supported by a VAD. Reconstruction of the pulmonary artery using a large pericardial patch and restoration of bicaval continuity were key to overcoming complex anatomical challenges.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.