Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018
Long-term outcomes of melody valve-in-valve implantation for bioprosthetic mitral valve dysfunction.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Joseph Timothy A, Eleid Mackram F, Cabalka Allison K, Maalouf Joseph F, Rihal Charanjit S
Аннотация
OBJECTIVES: This study reports long-term outcomes percutaneous Melody valve (Medtronic, Minneapolis, Minnesota) valve-in-valve therapy in patients with prosthetic valve dysfunction.
BACKGROUND: Repeat valve surgery is associated with high morbidity and mortality. Transcatheter mitral valve-in-valve is a promising alternative in patients at high-risk for cardiac surgery.
METHODS: We conducted a retrospective cohort analysis of 13 patients who underwent Melody valve-in-valve for bioprosthetic dysfunction from July 2011 to October 2013.
RESULTS: Mean age was 74.4 years, 46% male, and STS score 13.5 ± 6.8%. All patients had NYHA class 3 or 4 symptoms with improvement to class 1 or 2 in 82% post procedure. Median follow-up was 4.5 years with longest follow-up of 5.5 years. Thirty-day mortality was 15.4% with 1-year mortality of 25% and no other reported deaths until 4.5 years. 76.9% of patients had mitral gradient of 5 mmHg or less immediately postprocedure. One patient required repeat valve procedure for structural deterioration at 4.4 years. At 1, 3, and 5 year follow-ups 75% of patients were NYHA class 1 or 2, mean gradients were 4.5 ± 0.6, 6.8 ± 0.5, and 7.5 ± 0.7, respectively. Using 4-point scale, mitral regurgitation postprocedure was 0.8 ± 0.6. At 1, 3, and 5 years this increased to 1.0 ± 1.1, 1.3 ± 1.3, and 2.5 ± 2.1, respectively.
CONCLUSIONS: Melody valve-in-valve therapy was effective with 1-year symptomatic improvement. Prosthesis deterioration requiring repeat intervention was observed in one patient. Larger cohorts with multicenter registries are needed to determine the role of this percutaneous valve-in-valve therapy as valve technology and procedural techniques improve.
BACKGROUND: Repeat valve surgery is associated with high morbidity and mortality. Transcatheter mitral valve-in-valve is a promising alternative in patients at high-risk for cardiac surgery.
METHODS: We conducted a retrospective cohort analysis of 13 patients who underwent Melody valve-in-valve for bioprosthetic dysfunction from July 2011 to October 2013.
RESULTS: Mean age was 74.4 years, 46% male, and STS score 13.5 ± 6.8%. All patients had NYHA class 3 or 4 symptoms with improvement to class 1 or 2 in 82% post procedure. Median follow-up was 4.5 years with longest follow-up of 5.5 years. Thirty-day mortality was 15.4% with 1-year mortality of 25% and no other reported deaths until 4.5 years. 76.9% of patients had mitral gradient of 5 mmHg or less immediately postprocedure. One patient required repeat valve procedure for structural deterioration at 4.4 years. At 1, 3, and 5 year follow-ups 75% of patients were NYHA class 1 or 2, mean gradients were 4.5 ± 0.6, 6.8 ± 0.5, and 7.5 ± 0.7, respectively. Using 4-point scale, mitral regurgitation postprocedure was 0.8 ± 0.6. At 1, 3, and 5 years this increased to 1.0 ± 1.1, 1.3 ± 1.3, and 2.5 ± 2.1, respectively.
CONCLUSIONS: Melody valve-in-valve therapy was effective with 1-year symptomatic improvement. Prosthesis deterioration requiring repeat intervention was observed in one patient. Larger cohorts with multicenter registries are needed to determine the role of this percutaneous valve-in-valve therapy as valve technology and procedural techniques improve.
Предметные рубрики MeSH
AgedAged, 80 and overBioprosthesisCardiac CatheterizationFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMaleMiddle AgedMitral ValveMitral Valve InsufficiencyMitral Valve StenosisProsthesis DesignProsthesis FailureRecovery of FunctionRetrospective StudiesRisk FactorsTime FactorsTreatment Outcome