m+Medelevator.RU
← Поиск публикаций
Korean journal of radiology · 2021

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis.

СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lim Su Jin, Kim Minjae, Suh Chong Hyun, Kim Sang Yeong, Shim Woo Hyun, Kim Sang Joon

Аннотация

OBJECTIVE: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield.

MATERIALS AND METHODS: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI.

RESULTS: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I² statistic showed significant heterogeneity (I² = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31).

CONCLUSION: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты