m+Medelevator.RU
← Поиск публикаций
Translational vision science & technology · 2026

Design and Preclinical Validation of an Eyeglass-Coupled Perilimbal Antenna for Retinal Prostheses With a Biocompatible Graft Technique.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Cheng-Yung, Lai Tso-Ting, Chiang Chien-Yu, Wang Yun-Chen, Lin San-Yuan, Chiang Yi-Ju, Yang Yun-Ta, Yang Chang-Hao, Fan Long-Sheng

Аннотация

PURPOSE: To present a novel eyeglass-coupled perilimbal antenna for retinal prostheses and evaluate preclinical biocompatibility and ocular surface effects using a refined, graft-assisted implantation technique.

METHODS: The structural, mechanical, and functional properties of the antenna were assessed, including buffering systems for tissue resilience. Coupling between the eyeglass-rim-mounted emitter and perilimbal receiver was optimized through finite-element electromagnetic simulation and validated in electrolyte solution. A preclinical study was performed in 11 eyes of six Lanyu minipigs, in which antennas were implanted using a refined surgical technique and covered with amniotic membrane, porcine small intestinal submucosa, or pericardium graft. Postoperative evaluations over 6 months included serial external eye photography, anterior segment optical coherence tomography (AS-OCT), tear secretion testing, tear cytokine profiling, and conjunctival impression cytology.

RESULTS: All eyes showed stable healing without exposure, infection, or granulation. ASOCT revealed no significant change in perilimbal conjunctival thickness (400.5 ± 89.6 µm baseline vs. 399.4 ± 158.2 µm at 6 months; P = 0.612). Coverage materials thinned significantly (360.7 ± 119.5 µm at 1 month vs. 71.4 ± 103.0 µm at 6 months; P = 0.018) without adverse ocular effects. Transient postoperative elevations of tear cytokines (IL-1β, IL-8, IL-6) normalized over time. Tear production, conjunctival redness, and goblet cell density returned to baseline levels.

CONCLUSIONS: The eyeglass-coupled perilimbal antenna enabled efficient transmission with preserved ocular surface integrity. Graft-assisted implantation ensured stability and biocompatibility, serving as a safe interface for retinal prostheses.

TRANSLATIONAL RELEVANCE: A novel perilimbal antenna design enables efficient wireless transmission and biocompatible integration for next-generation retinal prostheses.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты