m+Medelevator.RU
← Поиск публикаций
Circulation. Arrhythmia and electrophysiology · 2021

Circular Multielectrode Pulsed Field Ablation Catheter Lasso Pulsed Field Ablation: Lesion Characteristics, Durability, and Effect on Neighboring Structures.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yavin Hagai, Brem Erez, Zilberman Israel, Shapira-Daniels Ayelet, Datta Keshava, Govari Assaf, Altmann Andres, Anic Ante, Wazni Oussama, Anter Elad

Аннотация

BACKGROUND: Pulsed field ablation (PFA) is a nonthermal energy with potential safety advantages over radiofrequency ablation. This study investigated a novel PFA system-a circular multielectrode catheter (PFA lasso) and a multichannel generator designed to work with Carto 3 mapping system.

METHODS: A 7.5F bidirectional circular catheter with 10 electrodes and variable expansion was designed for PFA (biphasic, 1800 Volts). This study included a total of 16 swine used to investigate the following 3 experimental aims: Aim 1 examined the feasibility to create a right atrial ablation line of block from the superior vena cava to the inferior vena cava. Aim 2 examined the effect of PFA on lesion maturation including durability after a 30-day survival period. Aim 3 examined the effect of high-intensity PFA (10 applications) on esophageal and phrenic nerve tissue in comparison to normal intensity radiofrequency ablation (1-2 applications). Histopathologic analysis of all cardiac, esophageal, and phrenic nerve tissue was performed.

RESULTS: Acute line of block was achieved in 12/12 swine (100%) and required a total PFA time of 14 seconds (interquartile range [IQR], 9-24.5) per line. Ablation line durability after 28±3 days was maintained in 11/12 (91.7%) swine. PFA resulted in transmural lesions in 179/183 (97.8%) sections and a median lesion width of 14.2 mm. High-intensity PFA (9 [IQR, 8-14] application) had no effect on the esophagus while standard intensity radiofrequency ablation (1.5 [IQR, 1-2] applications) resulted in deep esophageal tissue injury involving the muscularis propria and adventitia layers. High-intensity PFA (16 [IQR, 10-28] applications) has no effect on phrenic nerve function and structure while standard dose radiofrequency ablation (1.5 [IQR, 1-2] applications) resulted in acute phrenic nerve paralysis.

CONCLUSIONS: In this preclinical model, a multielectrode circular catheter and multichannel generator produced durable atrial lesions with lower vulnerability to esophageal or phrenic nerve damage.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты