MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(02)01894-1

Медицинская библиотека · Journal of cataract and refractive surgery · 2003

Corneal topographic results after eccentric, biconvex penetrating keratoplasty.

Kerényi Agnes, Süveges Ildikó

СтатьяПеревод в очереди

Аннотация

PURPOSE: To study the surgical outcomes and postoperative corneal topographies in 5 patients who had eccentric, biconvex penetrating keratoplasty (PKP) for peripheral corneal disorders whose extent did not allow the use of round grafts without involving the center of the cornea.

SETTING

1st Department of Ophthalmology, Semmelweis University, Medical School, Budapest, Hungary.

METHODS

Eccentric, biconvex PKP that spared the optical axis of the cornea was performed in 5 eyes. Indications for surgery were perforated peripheral ulcerative keratitis (n = 3), extensive infiltrated peripheral ulcerative keratitis with impending perforation (n = 1), and ulcerated corneal degeneration caused by an intracameral foreign body for 9 years (n = 1). Computer-assisted corneal topography was performed postoperatively. The follow-up ranged from 8 to 27 months.

RESULTS

All grafts were tectonically effective. Postoperative corneal topography showed normal central corneal regularity in 4 cases (1 case, normal pattern with surface regularity index [SRI] and surface asymmetry index [SAI] within the normal range; 3 cases, normal surface regularity within the central area of the cornea but moderate or high central corneal asymmetry). One eye had irregular astigmatism with a high SRI and SAI. In the first 4 cases, the best spectacle-corrected visual acuity was 0.8 (20/25) or better.

CONCLUSIONS

The results show that eccentric, biconvex PKP sparing the central cornea may be an option in some eyes with perforated peripheral corneal disorders. Postoperative visual acuity may be good as the procedure may result in a regular central anterior corneal surface.

Для цитирования: Kerényi Agnes, Süveges Ildikó. Corneal topographic results after eccentric, biconvex penetrating keratoplasty.. Journal of cataract and refractive surgery. 2003. DOI: 10.1016/s0886-3350(02)01894-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.