Precision-Guided Suprachoroidal Injection Using Ultrasound Biomicroscopy and Custom-Length Microneedles.

Gupta Puranjay, Kao Emily, Chadwick William F, Alahmadi Reem, Heiferman Michael J

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Suprachoroidal (SC) injection enables targeted posterior drug delivery but relies on subjective tactile feedback to confirm depth. This can require multiple passes or cause intravitreal delivery, increasing patient discomfort and complication risk. This study evaluates whether ultrasound biomicroscopy (UBM) can guide custom needle selection based on scleral thickness to improve first-pass SC injection success.

PATIENTS AND

METHODS

Ten ex vivo porcine eyes underwent pre-injection UBM to measure scleral thickness. Custom-length needles (0.5-1.5 mm) were selected accordingly. SC injections were performed under UBM guidance, with imaging confirming entry and injectate spread.

RESULTS

UBM confirmed successful SC injection in all specimens, with hypoechoic separation between sclera and choroid. Post-injection, scleral thickness increased significantly (1.13 ± 0.13 mm to 2.28 ± 0.19 mm, P < .0001), validating drug delivery.

CONCLUSION

UBM-guided needle selection enables accurate SC injection and may reduce failed attempts. This approach could enhance the efficacy of SC delivery and support broader clinical use across posterior segment diseases.

Для цитирования: Gupta Puranjay, Kao Emily, Chadwick William F, Alahmadi Reem, Heiferman Michael J. Precision-Guided Suprachoroidal Injection Using Ultrasound Biomicroscopy and Custom-Length Microneedles.. Ophthalmic surgery, lasers & imaging retina. 2026. DOI: 10.3928/23258160-20260521-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.