MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvsv.2024.101943

Медицинская библиотека · Journal of vascular surgery. Venous and lymphatic disorders · 2024

Predicting inferior vena cava filter complications using machine learning.

Li Ben, Eisenberg Naomi, Beaton Derek, Lee Douglas S, Al-Omran Leen, Wijeysundera Duminda N, Hussain Mohamad A, Rotstein Ori D, de Mestral Charles, Mamdani Muhammad, Roche-Nagle Graham, Al-Omran Mohammed

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Inferior vena cava (IVC) filter placement is associated with important long-term complications. Predictive models for filter-related complications may help guide clinical decision-making but remain limited. We developed machine learning (ML) algorithms that predict 1-year IVC filter complications using preoperative data.

METHODS

The Vascular Quality Initiative database was used to identify patients who underwent IVC filter placement between 2013 and 2024. We identified 77 preoperative demographic and clinical features from the index hospitalization when the filter was placed. The primary outcome was 1-year filter-related complications (composite of filter thrombosis, migration, angulation, fracture, and embolization or fragmentation, vein perforation, new caval or iliac vein thrombosis, new pulmonary embolism, access site thrombosis, or failed retrieval). The data were divided into training (70%) and test (30%) sets. Six ML models were trained using preoperative features with 10-fold cross-validation (Extreme Gradient Boosting, random forest, Naïve Bayes classifier, support vector machine, artificial neural network, and logistic regression). The primary model evaluation metric was area under the receiver operating characteristic curve (AUROC). Model robustness was assessed using calibration plot and Brier score. Performance was evaluated across subgroups based on age, sex, race, ethnicity, rurality, median Area Deprivation Index, planned duration of filter, landing site of filter, and presence of prior IVC filter placement.

RESULTS

Overall, 14,476 patients underwent IVC filter placement and 584 (4.0%) experienced 1-year filter-related complications. Patients with a primary outcome were younger (59.3 ± 16.7 years vs 63.8 ± 16.0 years; P < .001) and more likely to have thrombotic risk factors including thrombophilia, prior venous thromboembolism (VTE), and family history of VTE. The best prediction model was Extreme Gradient Boosting, achieving an AUROC of 0.93 (95% confidence interval, 0.92-0.94). In comparison, logistic regression had an AUROC of 0.63 (95% confidence interval, 0.61-0.65). Calibration plot showed good agreement between predicted/observed event probabilities with a Brier score of 0.07. The top 10 predictors of 1-year filter-related complications were (1) thrombophilia, (2) prior VTE, (3) antiphospholipid antibodies, (4) factor V Leiden mutation, (5) family history of VTE, (6) planned duration of IVC filter (temporary), (7) unable to maintain therapeutic anticoagulation, (8) malignancy, (9) recent or active bleeding, and (10) age. Model performance remained robust across all subgroups.

CONCLUSIONS

We developed ML models that can accurately predict 1-year IVC filter complications, performing better than logistic regression. These algorithms have potential to guide patient selection for filter placement, counselling, perioperative management, and follow-up to mitigate filter-related complications and improve outcomes.

Для цитирования: Li Ben, Eisenberg Naomi, Beaton Derek, Lee Douglas S, Al-Omran Leen, Wijeysundera Duminda N, Hussain Mohamad A, Rotstein Ori D, de Mestral Charles, Mamdani Muhammad, Roche-Nagle Graham, Al-Omran Mohammed. Predicting inferior vena cava filter complications using machine learning.. Journal of vascular surgery. Venous and lymphatic disorders. 2024. DOI: 10.1016/j.jvsv.2024.101943.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.