MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajoc.2025.102328

Медицинская библиотека · American journal of ophthalmology case reports · 2025

Post-operative cosmesis of autologous capsular patch grafts in tube shunt surgery: Case series of 18 eyes.

Ciulla Lauren, Wang Jessie, Qiu Mary

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Capsule tissue from preexisting tube shunts can be used as autologous patch grafts in patients that require tube revision, exchange, or removal.

PURPOSE: To retrospectively describe the use of autologous capsular patch grafts for tube shunt surgeries and demonstrate their cosmetic outcomes.

METHODS

Tube shunt surgeries using autologous capsular patch grafts from March 2, 2020 through August 10, 2023 by a single surgeon at the University of Chicago were included in this case series.

RESULTS

18 patients had capsule patch grafts during tube shunt surgeries. 16 patients have post-operative photos available. 18 patients had capsule patch grafts during tube shunt surgeries. 16 patients have post-operative photos available. There were 2 cases of failed superotemporal tube shunts for which a second inferonasal tube was placed. There were 9 cases of same-quadrant Ahmed FP7 to BGI-350 exchange: 7 for uncontrolled IOP, 2 for tube erosion. There were also five cases of same-quadrant exchange with varying tube types for indications such as erosion, hypotony, and elevated intra-ocular pressure. There was also one case of different quadrant exchange for impending endothelial keratoplasty for corneal failure and poor cosmesis of the tube. Finally, there was one case of tube shunt removal for erosion with goniotomy. Duration of post-operative follow-up averaged 57 weeks (range 2-178 weeks). There were no complications related to the autografts.

CONCLUSION

Autologous capsular patch grafts can be efficacious in tube shunt surgeries with good cosmetic outcome. Longer follow up and larger trials are needed.

Для цитирования: Ciulla Lauren, Wang Jessie, Qiu Mary. Post-operative cosmesis of autologous capsular patch grafts in tube shunt surgery: Case series of 18 eyes.. American journal of ophthalmology case reports. 2025. DOI: 10.1016/j.ajoc.2025.102328.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.