Archivos de la Sociedad Espanola de Oftalmologia · 2010
[Simultaneous pars plana vitrectomy and glaucoma drainage device implant].
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Suárez-Fernández M J, Gutiérrez-Díaz E, Julve San Martín A, Fernández-Reyes M F, Mencía-Gutiérrez E
Аннотация
PURPOSE: To evaluate intraocular pressure (IOP) and visual acuity (VA) results after glaucoma drainage device (GDD) implantation combined with simultaneous pars plana vitrectomy (PPV).
MATERIAL AND METHODS: Retrospective review of 8 eyes (7 patients). The diagnosis was neovascular glaucoma (NVG) secondary to proliferative diabetic retinopathy in 4 eyes, in a which a double plate Molteno implant was placed, and glaucoma secondary (GS) to complicated cataract surgery in 3 eyes and penetrating trauma in one eye, in which a glaucoma Ahmed valve was implanted.
RESULTS: Mean preoperative IOP was 35.77 mmHg (20-50) and 11.5 mmHg (2-20) postoperatively, and mean number hypotensive drugs was decreased from 2.33 (0-3) before surgery to 0.62 (0-3) after it. Preoperative VA in NVG was light perception or counting fingers, and it was lost in three eyes. In GS, VA before surgery was below 0.1 in all eyes, and three months after surgery mean VA was 0.42 (0.1-0.8). Mean follow-up was 10.12 months (5-27). The complications were tube obstruction in two cases, one of these presenting also a suprachoroidal hemorrage and ptisis bulbi, plate exposure in one case, and bullous keratopathy as a late complication in another eye.
CONCLUSIONS: The VA and IOP were well controlled with this procedure in GS. In NVG, IOP was controlled, but visual results were poor due to complications and the underlying pathology.
MATERIAL AND METHODS: Retrospective review of 8 eyes (7 patients). The diagnosis was neovascular glaucoma (NVG) secondary to proliferative diabetic retinopathy in 4 eyes, in a which a double plate Molteno implant was placed, and glaucoma secondary (GS) to complicated cataract surgery in 3 eyes and penetrating trauma in one eye, in which a glaucoma Ahmed valve was implanted.
RESULTS: Mean preoperative IOP was 35.77 mmHg (20-50) and 11.5 mmHg (2-20) postoperatively, and mean number hypotensive drugs was decreased from 2.33 (0-3) before surgery to 0.62 (0-3) after it. Preoperative VA in NVG was light perception or counting fingers, and it was lost in three eyes. In GS, VA before surgery was below 0.1 in all eyes, and three months after surgery mean VA was 0.42 (0.1-0.8). Mean follow-up was 10.12 months (5-27). The complications were tube obstruction in two cases, one of these presenting also a suprachoroidal hemorrage and ptisis bulbi, plate exposure in one case, and bullous keratopathy as a late complication in another eye.
CONCLUSIONS: The VA and IOP were well controlled with this procedure in GS. In NVG, IOP was controlled, but visual results were poor due to complications and the underlying pathology.
Предметные рубрики MeSH
AgedAged, 80 and overCataract ExtractionChoroid HemorrhageCorneal DiseasesDiabetic RetinopathyEquipment FailureEye Injuries, PenetratingFemaleGlaucomaGlaucoma Drainage ImplantsGlaucoma, NeovascularHumansIntraocular PressureMaleMiddle AgedMolteno ImplantsPostoperative ComplicationsRetrospective StudiesTreatment OutcomeVitrectomy