Ultrasound energy in phacoemulsification: a comparative analysis of phaco-chop and stop-and-chop techniques according to the degree of nuclear density.
Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Park Jung Hyun, Lee Sang Mok, Kwon Ji-Won, Kim Mee Kum, Hyon Joon Young, Wee Won Ryang, Lee Jin Hak, Han Young Keun
Аннотация
BACKGROUND AND OBJECTIVE: To evaluate the amount of ultrasound energy used, corneal endothelial cell loss, and central corneal thickness using the phaco-chop and stop-and-chop techniques for cataracts with different degrees of nuclear density.
PATIENTS AND METHODS: One hundred two eyes of 51 patients with bilateral senile cataract were included. Each eye was randomly assigned to have either phaco-chop or stop-and-chop nucleofractis during phacoemulsification. The groups were divided into two subgroups according to the nuclear density. The effective phacoemulsification time, endothelial cell density, and central corneal thickness were analyzed.
RESULTS: The mean effective phacoemulsification time was similar between the groups in moderately dense nuclei (2.17 +/- 1.33 vs 1.33 +/- 1.05 seconds; P = .41). However, the phaco-chop technique required less effective phacoemulsification time than the stop-and-chop technique in dense nuclei (3.86 +/- 4.18 vs 6.70 +/- 5.43 seconds; P = .01). The endothelial cell loss and the central corneal thickness did not vary significantly between the groups.
CONCLUSION: The phaco-chop technique requires lower ultrasound energy for nuclear management than the stop-and-chop technique in dense cataracts and the resulting endothelial loss was similar in both techniques.
PATIENTS AND METHODS: One hundred two eyes of 51 patients with bilateral senile cataract were included. Each eye was randomly assigned to have either phaco-chop or stop-and-chop nucleofractis during phacoemulsification. The groups were divided into two subgroups according to the nuclear density. The effective phacoemulsification time, endothelial cell density, and central corneal thickness were analyzed.
RESULTS: The mean effective phacoemulsification time was similar between the groups in moderately dense nuclei (2.17 +/- 1.33 vs 1.33 +/- 1.05 seconds; P = .41). However, the phaco-chop technique required less effective phacoemulsification time than the stop-and-chop technique in dense nuclei (3.86 +/- 4.18 vs 6.70 +/- 5.43 seconds; P = .01). The endothelial cell loss and the central corneal thickness did not vary significantly between the groups.
CONCLUSION: The phaco-chop technique requires lower ultrasound energy for nuclear management than the stop-and-chop technique in dense cataracts and the resulting endothelial loss was similar in both techniques.