DOI 10.1186/s12902-026-02170-9

Медицинская библиотека · BMC endocrine disorders · 2026

Diagnostic utility of morning serum cortisol in predicting short synacthen test outcomes in outpatients with suspected adrenal insufficiency.

Sheikh-Ahmad Mohammad, Rosenblat Ilana, Salameh Shadi, Dakwar Balsam, Shalata Anan, Yosefia Sawsan, Rabani Hadas, Jovanovic Katya, Saiegh Leonard

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Adrenal insufficiency (AI) often presents with non-specific symptoms such as fatigue, posing a diagnostic challenge in outpatient settings. While the 250 µg short Synacthen test (SST) remains the gold standard for assessing adrenal function, it may be resource-intensive and inconvenient. Morning serum cortisol (MSC) offers a potential alternative for initial screening, but its predictive value for SST outcomes in community-referred patients remains uncertain.

OBJECTIVE

To evaluate the correlation between MSC and SST outcomes in outpatients presenting with non-specific symptoms suggestive of AI, and to identify MSC thresholds predictive of normal SST.

METHODS

This retrospective cross-sectional study analyzed 228 SSTs performed between 2006 and 2021 on adult outpatients without known endocrine disease. MSC was measured prior to 250 µg intravenous Synacthen administration, with cortisol levels re-assessed 30 min post-injection (Cort30). Pearson correlation and Receiver Operating Characteristic (ROC) curve analysis were used to assess associations and identify optimal MSC cutoffs for predicting normal SST, defined as Cort30 ≥ 18 µg/dL (500 nmol/L).

RESULTS

The mean MSC and Cort30 values were 9.4 ± 3.9 (259 ± 108 nmol/L) and 20.8 ± 7 µg/dL (574 ± 193 nmol/L), respectively. Applying ROC analysis, MSC threshold of 8.7 µg/dL (240 nmol/L) yielded the optimal performance, providing 83.2% sensitivity, 49.5% specificity, 69% PPV, 68.9% NPV, and 68.9% accuracy. Among patients with MSC ≥ 8.7 µg/dL (240 nmol/L), 83.2% had normal SST. MSC values of 3 µg/dL (83 nmol/L) and 15.5 µg/dL (428 nmol/L) demonstrated 100% sensitivity and 100% specificity for predicting normal SST, respectively.

CONCLUSION

In patients referred from the community with non-specific symptoms, MSC measurement may provide a useful adjunct for evaluating adrenal function, especially when MSC results are at the extremes. CLINICAL TRIAL NUMBER: 0133-21-BNZ.

Для цитирования: Sheikh-Ahmad Mohammad, Rosenblat Ilana, Salameh Shadi, Dakwar Balsam, Shalata Anan, Yosefia Sawsan, Rabani Hadas, Jovanovic Katya, Saiegh Leonard. Diagnostic utility of morning serum cortisol in predicting short synacthen test outcomes in outpatients with suspected adrenal insufficiency.. BMC endocrine disorders. 2026. DOI: 10.1186/s12902-026-02170-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.