MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8159.2005.08672.x

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2005

Atrial pacing should be used more frequently in sinus node disease.

Tripp Ian G, Armstrong Guy P, Stewart James T, Hood Margaret A, Smith Warren M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Single lead atrial (AAI(R)) pacing for sick sinus syndrome provides physiological pacing and is less expensive than a dual chamber system. Compared with ventricular-based pacing, it maintains the normal cardiac depolarization sequence, is associated with less atrial fibrillation and heart failure, and avoids pacemaker syndrome. We sought whether it is possible to select patients for AAI(R) pacing with a low likelihood of subsequent ventricular pacing, and whether this approach was cost-effective.

METHODS

A retrospective review was conducted of AAI(R) pacemaker implantations. Patients requiring a further procedure for insertion of a ventricular lead (for DDD(R) or VVI(R) pacing) were compared with those who remained atrially paced.

RESULTS

2.7% (117 of 4,366) of implants were AAI(R), compared with less than 1% overall for New Zealand and Australia. During follow-up of 3.5 (2.3, 7.7) years, insertion of a ventricular lead was required in 14 (12%), and was more likely in those with pre-existing PR interval >0.20 seconds (odds ratio 7.8, P = 0.003) or left bundle branch block (LBBB, odds ratio 17, P = 0.037). Right bundle branch block, left anterior fascicular block, or history of paroxysmal atrial fibrillation were not more frequent in the group requiring ventricular pacing, and preimplantation Wenckebach point was not different. The most efficient strategy was initial AAIR implantation in all except those with LBBB or PR interval >0.20 seconds. Compared with routine DDDR implantation, cost was reduced by 20%, with a 1.4% annual incidence of further procedures.

CONCLUSION

AAIR is the appropriate pacing choice for sick sinus syndrome without LBBB or PR interval >0.20 seconds.

Для цитирования: Tripp Ian G, Armstrong Guy P, Stewart James T, Hood Margaret A, Smith Warren M. Atrial pacing should be used more frequently in sinus node disease.. Pacing and clinical electrophysiology : PACE. 2005. DOI: 10.1111/j.1540-8159.2005.08672.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.