MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm15082902

Медицинская библиотека · Journal of clinical medicine · 2026

Comparison of Fascicular Turnover Flap and Autograft in a Rat Facial Nerve Model.

Shpitser Ivan, Gabriyanchik Mark, Fayzullin Alexey, Khristidis Yana, Salikhov Kamil, Startseva Olesya, Kolesnikova Olga, Pirogov Kirill, Timashev Peter, Vedyaeva Anna

СтатьяПеревод в очереди

Аннотация

Background

Fascicular turnover flap (FTF) is a donor-sparing option for segmental facial nerve repair. This study compared autologous nerve grafting with proximally based and distally based FTF in a rat facial nerve model.

Methods

Adult male Wistar rats were randomized to autograft, proximal FTF, or distal FTF (n = 8 per group). A single additional animal with an untreated defect served as a qualitative histological reference. The prespecified primary endpoint was whisker motion amplitude at week 8; the secondary endpoints were central section histomorphometry (nerve tissue area, µm2) and variability metrics (IQR, SD, and coefficient of variation) as measures of reproducibility. Non-parametric tests (Kruskal-Wallis; Mann-Whitney U) were used; pairwise functional comparisons were Holm-corrected; and effect sizes were expressed as Cliff's δ.

Results

At week 8, the overall functional comparison was significant (Kruskal-Wallis p = 0.047), but no pairwise contrast remained significant after Holm correction. Functional recovery was highest in the autograft group, followed by proximal FTF and distal FTF. Both FTF groups showed lower inter-animal variability than autograft for the week-8 functional endpoint, with the distal FTF showing the lowest dispersion. Central section nerve area comparisons did not reach global significance; effect sizes and descriptive statistics favored autograft, and a single unadjusted pairwise contrast (autograft > proximal FTF) should be interpreted cautiously.

Conclusions

Both FTF configurations achieved measurable functional and structural regeneration while avoiding an additional free donor nerve graft. Within an 8-week window, autograft remained the benchmark. Between FTF variants, distal FTF produced more stable functional outcomes, but this did not translate into superior functional recovery. Confirmation in larger, balanced cohorts with longer follow-up and vascular/neural labeling is warranted.

Для цитирования: Shpitser Ivan, Gabriyanchik Mark, Fayzullin Alexey, Khristidis Yana, Salikhov Kamil, Startseva Olesya, Kolesnikova Olga, Pirogov Kirill, Timashev Peter, Vedyaeva Anna. Comparison of Fascicular Turnover Flap and Autograft in a Rat Facial Nerve Model.. Journal of clinical medicine. 2026. DOI: 10.3390/jcm15082902.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.