MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s276226

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2020

Scleral Fixation of Single-Piece Foldable IOL Using Double-Flanged Technique.

Samir Ahmed, ElHag Yasser G, Elsayed Ayman M Abdelrahman, Elsayed Tamer Gamal, Lotfy Ayman

СтатьяПеревод в очереди

Аннотация

PURPOSE: To describe the efficiency and visual results of a new method of transconjunctival intrascleral fixation of single-piece foldable IOL using double-flanged 6/0 prolene suture.

MATERIALS AND

METHODS

Seventeen aphakic eyes of 17 patients without adequate capsular support were involved in this study. Lens was prepared by passing the 6/0 prolene suture in a track in the haptic of single-piece foldable IOL created by 31 g needle. The 6/0 prolene suture was retrieved through a 30 g needle transconjunctivally to outside the globe; then, IOL was implanted and a terminal bulb was created at the outer end of the prolene suture.

RESULTS

All cases were aphakic after complicated phacoemulsification. In 10 cases hydrophilic IOLs were used and in 7 cases hydrophobic IOLs were used. There is clear statistically significant difference between pre-UCVA and post- UCVA. Complications included suture slippage in 2 cases and prolene bulb exposure in one case. There was no significant difference in endothelial cell count and IOP before and after 3 months.

CONCLUSION

Transconjunctival intrascleral fixation of foldable single-piece IOLs is a safe efficient method for correcting aphakia.

Для цитирования: Samir Ahmed, ElHag Yasser G, Elsayed Ayman M Abdelrahman, Elsayed Tamer Gamal, Lotfy Ayman. Scleral Fixation of Single-Piece Foldable IOL Using Double-Flanged Technique.. Clinical ophthalmology (Auckland, N.Z.). 2020. DOI: 10.2147/opth.s276226.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.