MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14020507

Медицинская библиотека · Journal of clinical medicine · 2025

Short-Term Safety and Efficacy of PreserFlo™ Microshunt in Patients with Refractory Intraocular Pressure Elevation After Dexamethasone Implant Intravitreal Injection.

Bourauel Leonie, Petrak Michael, Holz Frank G, Mercieca Karl, Weber Constance

СтатьяПеревод в очереди

Аннотация

Background

The PreserFlo™ MicroShunt (PFMS) is a bleb-forming device considered to be less invasive than traditional glaucoma surgery such as trabeculectomy. This study evaluates the 1-year success rates as well as safety profile of PFMS in patients having high intraocular pressure (IOP) and/or glaucoma refractory to drop therapy with a history of prior intravitreal dexamethasone therapy.

Methods

A total of 16 eyes after PFMS implantation due to elevated IOP after intravitreal dexamethasone implant (DEX-I) administration were included in this retrospective cohort study. Success rates and secondary outcomes were evaluated.

Results

Qualified and complete success rates at 12 months, respectively, were 14/16 and 12/16 eyes for criterion A, 13/16 and 11/16 eyes for B, 13/16 and 11/16 eyes for C, and 6/16 and 6/16 eyes for D. The overall mean (range) preoperative IOP decreased from 27 (16-38) mmHg to 13 (10-17) mmHg at 12 months. BCVA was not significantly different up to 12 months (p = 0.63). The preoperative mean (range) number of medications decreased from 3.56 (2-4) to 0.31 (0-3) at 12 months. One eye underwent needling twice, and two eyes were revised surgically. One patient needed replacement of the PFMS. There were no hypotony-related complications.

Conclusions

The PFMS is an effective surgical option for patients with steroid-induced IOP elevation. It demonstrates satisfactory short-term success rates, a reduced need for pressure-lowering eye drops, an excellent safety profile with minimal postoperative care, and a low complication rate. Additional interventions such as needling or revisions were infrequently necessary. However, PFMS may not be the ideal choice for cases requiring a low target pressure (≤12 mmHg).

Для цитирования: Bourauel Leonie, Petrak Michael, Holz Frank G, Mercieca Karl, Weber Constance. Short-Term Safety and Efficacy of PreserFlo™ Microshunt in Patients with Refractory Intraocular Pressure Elevation After Dexamethasone Implant Intravitreal Injection.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14020507.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.