MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00276-018-2127-9

Медицинская библиотека · Surgical and radiologic anatomy : SRA · 2018

Ultrasound-guided decompression surgery of the tarsal tunnel: a novel technique for the proximal tarsal tunnel syndrome-Part II.

Fernández-Gibello Alejandro, Moroni Simone, Camuñas Gabriel, Montes Rubén, Zwierzina Marit, Tasch Christoph, Starke Vasco, Sañudo José, Vazquez Teresa, Konschake Marko

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study is to provide a safe ultrasound-guided minimally invasive surgical approach for a proximal tarsal tunnel release concerning nerve entrapments.

METHODS AND

RESULTS

The study was carried out on ten fresh-frozen feet. All of them were examined by high resolution ultrasound at the medial ankle region. The surgical approach was marked throughout the course of the flexor retinaculum (laciniate ligament). Once the previous steps were done, the flexor retinaculum release technique was carried out with a 2-mm entry only. As a result, an effective and safe release of the flexor retinaculum was obtained in all fresh-frozen feet.

CONCLUSION

The results of our anatomic study indicate that our novel ultrasound-guided minimally invasive surgical approach for the release of the flexor retinaculum might be an effective, safe and quick decompression technique treating selected patients with a proximal tarsal tunnel syndrome.

Для цитирования: Fernández-Gibello Alejandro, Moroni Simone, Camuñas Gabriel, Montes Rubén, Zwierzina Marit, Tasch Christoph, Starke Vasco, Sañudo José, Vazquez Teresa, Konschake Marko. Ultrasound-guided decompression surgery of the tarsal tunnel: a novel technique for the proximal tarsal tunnel syndrome-Part II.. Surgical and radiologic anatomy : SRA. 2018. DOI: 10.1007/s00276-018-2127-9.