The international journal of cardiovascular imaging · 2020
Predictors of zero X ray procedures in supraventricular arrhythmias ablation.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Di Cori Andrea, Zucchelli Giulio, Segreti Luca, Barletta Valentina, Viani Stefano, Paperini Luca, Della Tommasina Veronica, Cellamaro Tea, Vecchi Andrea, Soldati Ezio, Bongiorni Maria Grazia
Аннотация
To evaluate predictors of zero-X ray procedures for supraventricular arrhythmias (SVT) using minimally fluoroscopic approach (MFA). Patients referred for RF catheter ablation of SVT were admitted for a MFA with an electro-anatomical navigation system or a conventional fluoroscopic approach (ConvA). Exclusion criterion was the need to perform a transseptal puncture. 206 patients (98 men, age 53 ± 19 years) underwent an EP study, 93 (45%) with an MFA and 113 (55%) with a ConvA. Fifty-five had no inducible arrhythmias (EPS). Fifty-four had AV nodal reentrant tachycardia (AVNRT), 49 patients had typical atrial flutter (AFL), 37 had AV reciprocating tachycardia (AVRT/WPW), 11 had focal atrial tachycardia (AT), and underwent a RF ablation. X-ray was not used at all in 51/93 (58%) procedures (zero X ray). MFA was associated with a significant reduction in total fluoroscopy time (5.5 ± 10 vs 13 ± 18 min, P = 0.01) and operator radiation dose (0.8 ± 2.5 vs 3 ± 8.2 mSV, P < 0.05). The greatest absolute dose reduction was observed in AVNRT (0.1 ± 0.3 vs 5.1 ± 10 mSV, P = 0.01, 98% relative dose reduction) and in AFL (1.3 ± 3.6 vs 11 ± 16 mSV, P = 0.003, 88% relative dose reduction) groups. Both AVNRT or AFL resulted the only statistically significant predictors of zero x ray at multivariate analysis (OR 4.5, 95% CI 1.5-13 and OR 5, 95% CI 1.7-15, P < 0.001, respectively). Success and complication rate was comparable between groups (P = NS). Using MFA for SVT ablation, radiological exposure is significantly reduced. Type of arrhythmia is the strongest predictor of zero X ray procedure.
Предметные рубрики MeSH
Action PotentialsAdultAgedAtrial FlutterCatheter AblationElectrophysiologic Techniques, CardiacFemaleFluoroscopyHeart RateHumansMaleMiddle AgedOccupational ExposurePatient SafetyRadiation DosageRadiation ExposureRetrospective StudiesRisk AssessmentRisk FactorsTachycardia, Atrioventricular Nodal ReentryTachycardia, SupraventricularTime FactorsTreatment Outcome