m+Medelevator.RU
← Поиск публикаций
Arquivos de neuro-psiquiatria · 2026

Transcranial Doppler findings in patients with COVID-19: a prospective observational study.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Santos Marcella Barreto, Silveira Ana Flávia, Andrade João Brainer Clares de, Rocha Eva Carolina, Moraes Fabiano Moulin de, Martins Hanna Nery Ferraz, Rodrigues Daniela Laranja Gomes, Silva Gisele Sampaio

Аннотация

BACKGROUND: Transcranial Doppler (TCD) is a diagnostic tool to detect real-time spontaneous microembolic signals (MESs) in intracranial circulation. Critically-ill coronavirus disease 2019 (COVID-19) patients may present an increased likelihood of MESs due to systemic inflammation and hypercoagulability.

OBJECTIVE: To assess the presence of MESs and other TCD parameters, including cerebral blood flow velocity (CBFV), pulsatility, and resistance indices, and to calculate the estimated cerebral perfusion pressure (eCPP) in patients with and without COVID-19.

METHODS: The TCD monitoring was performed for 1 hour in both middle cerebral arteries (MCAs) of adult patients in the Intensive Care Unit (ICU) with confirmed COVID-19 infection. The eCPP was calculated by multiplying the mean arterial pressure (MAP) by the ratio of end-diastolic velocity to mean CBFV, then adding 14 mmHg.

RESULTS: We evaluated 31 subjects: 11 intubated COVID-19 patients, 10 non-intubated COVID-19 patients, and 10 intubated non-COVID-19 patients. Patient ages ranged from 29 to 84 (median: 62; interquartile range [IQR]: 50-70) years, with 64.5% being male individuals. A total of 17 (54.8%) subjects died during hospitalization, and 2 patients (6.45%) lacked an ultrasonographic signal via the transtemporal window. No MESs were detected. A positive correlation was found between the resistance index of MCAs (p = 0.390) and D-dimer (p = 0.049). In contrast, direct bilirubin (p = -0.494), C-reactive protein (CRP; p = -0.540), activated partial thromboplastin time (aPTT; p = -0.495), and D-dimer (p = -0.439) were negatively correlated with eCPP.

CONCLUSION: No spontaneous cerebral microemboli were observed in this cohort, but patients with higher direct bilirubin, CRP, aPTT, and D-dimer presented lower eCPP.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты