Transcranial Doppler findings in patients with COVID-19: a prospective observational study.
Аннотация
BACKGROUND
Transcranial Doppler (TCD) is a diagnostic tool to detect real-time spontaneous microembolic signals (MESs) in intracranial circulation. Critically-ill coronavirus disease 2019 (COVID-19) patients may present an increased likelihood of MESs due to systemic inflammation and hypercoagulability.
OBJECTIVE
To assess the presence of MESs and other TCD parameters, including cerebral blood flow velocity (CBFV), pulsatility, and resistance indices, and to calculate the estimated cerebral perfusion pressure (eCPP) in patients with and without COVID-19.
METHODS
The TCD monitoring was performed for 1 hour in both middle cerebral arteries (MCAs) of adult patients in the Intensive Care Unit (ICU) with confirmed COVID-19 infection. The eCPP was calculated by multiplying the mean arterial pressure (MAP) by the ratio of end-diastolic velocity to mean CBFV, then adding 14 mmHg.
RESULTS
We evaluated 31 subjects: 11 intubated COVID-19 patients, 10 non-intubated COVID-19 patients, and 10 intubated non-COVID-19 patients. Patient ages ranged from 29 to 84 (median: 62; interquartile range [IQR]: 50-70) years, with 64.5% being male individuals. A total of 17 (54.8%) subjects died during hospitalization, and 2 patients (6.45%) lacked an ultrasonographic signal via the transtemporal window. No MESs were detected. A positive correlation was found between the resistance index of MCAs (p = 0.390) and D-dimer (p = 0.049). In contrast, direct bilirubin (p = -0.494), C-reactive protein (CRP; p = -0.540), activated partial thromboplastin time (aPTT; p = -0.495), and D-dimer (p = -0.439) were negatively correlated with eCPP.
CONCLUSION
No spontaneous cerebral microemboli were observed in this cohort, but patients with higher direct bilirubin, CRP, aPTT, and D-dimer presented lower eCPP.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.