ESC heart failure · 2022
Hypotension on cardiopulmonary stress test predicts 90 day mortality after LVAD implantation in INTERMACS 3-6 patients.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Maharaj Valmiki, Agdamag Arianne C, Duval Sue, Edmiston Jonathan, Charpentier Victoria, Fraser Meg, Hall Alexandra, Schultz Jessica, John Ranjit, Shaffer Andrew, Martin Cindy M, Thenappan Thenappan, Francis Gary S, Cogswell Rebecca, Alexy Tamas
Аннотация
AIMS: Cardiopulmonary stress test (CPX) is routinely performed when evaluating patient candidacy for left ventricular assist device (LVAD) implantation. The predictive value of hypotensive systolic blood pressure (SBP) response during CPX on clinical outcomes is unknown. This study aims to determine the effect of hypotensive SBP response during to clinical outcomes among patients who underwent LVAD implantation.
METHODS AND RESULTS: This was a retrospective single center study enrolling consecutive patients implanted with a continuous flow LVAD between 2011 and 2022. Hypotensive SBP response was defined as peak exercise SBP below the resting value. Multivariable Cox-regression analysis was performed to evaluate the relationship between hypotensive SBP response and all-cause mortality within 30 and 90 days of LVAD implantation. A subgroup analysis was performed for patients implanted with a HeartMate III (HM III) device. Four hundred thirty-two patients underwent LVAD implantation during the pre-defined period and 156 with INTERMACS profiles 3-6 met our inclusion criteria. The median age was 63 years (IQR 54-69), and 52% had ischaemic cardiomyopathy. Hypotensive SBP response was present in 35% of patients and was associated with increased 90 day all-cause mortality (unadjusted HR 9.16, 95% CI 1.98-42; P = 0.0046). Hazard ratio remained significant after adjusting for age, INTERMACS profile, serum creatinine, and total bilirubin. Findings were similar in the HM III subgroup.
CONCLUSIONS: Hypotensive SBP response on pre-LVAD CPX is associated with increased perioperative and 90 day mortality after LVAD implantation. Additional studies are needed to determine the mechanism of increased mortality observed.
METHODS AND RESULTS: This was a retrospective single center study enrolling consecutive patients implanted with a continuous flow LVAD between 2011 and 2022. Hypotensive SBP response was defined as peak exercise SBP below the resting value. Multivariable Cox-regression analysis was performed to evaluate the relationship between hypotensive SBP response and all-cause mortality within 30 and 90 days of LVAD implantation. A subgroup analysis was performed for patients implanted with a HeartMate III (HM III) device. Four hundred thirty-two patients underwent LVAD implantation during the pre-defined period and 156 with INTERMACS profiles 3-6 met our inclusion criteria. The median age was 63 years (IQR 54-69), and 52% had ischaemic cardiomyopathy. Hypotensive SBP response was present in 35% of patients and was associated with increased 90 day all-cause mortality (unadjusted HR 9.16, 95% CI 1.98-42; P = 0.0046). Hazard ratio remained significant after adjusting for age, INTERMACS profile, serum creatinine, and total bilirubin. Findings were similar in the HM III subgroup.
CONCLUSIONS: Hypotensive SBP response on pre-LVAD CPX is associated with increased perioperative and 90 day mortality after LVAD implantation. Additional studies are needed to determine the mechanism of increased mortality observed.