MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.8b01069

Медицинская библиотека · ACS sensors · 2018

Enhanced Signal Amplification in a Toll-like Receptor-4 Biosensor Utilizing Ferrocene-Terminated Mixed Monolayers.

Mayall Robert M, Renaud-Young Margaret, Gawron Erin, Luong Samantha, Creager Stephen, Birss Viola I

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A major challenge in effectively treating infections is to provide timely diagnosis of a bacterial or viral agent. Current cell culture methods require >24 h to identify the cause of infection. The Toll-like Receptor (TLR) family of proteins can identify classes of pathogens and has been shown to work well in an impedance-based biosensor, where the protein is attached to an electrode via a self-assembled monolayer (SAM). While the sensitivity of these sensors has been good, they contain a high resistance (>1 kΩ) SAM, generating relatively small signals and requiring longer data collection, which is ill-suited to implementation outside of a laboratory. Here, we describe a novel approach to increase the signal magnitude and decrease the measurement time of a TLR-4 biosensor by inserting a redox-active ferrocenyl-terminated alkanethiol into a mixed SAM containing hydroxyl- and carboxyl-terminated alkanethiols. The SAM formation and modification was confirmed via contact angle and X-ray photoelectron spectroscopy measurements, with TLR-4 immobilization demonstrated through a modified immunosorbent assay. It is shown that these TLR-4 biosensors respond selectively to their intended target, Gram-negative bacteria at levels between 1 and 105 lysed cells/mL, while remaining insensitive to Gram-positive bacteria or viral particles at up to 105 particles/mL. Furthermore, the signal enhancement due to the addition of ferrocene decreased the measurement time to less than 1 min and has enabled this sensor to be used with an inexpensive, portable, hand-held potentiostat that could be easily implemented in field settings.

Для цитирования: Mayall Robert M, Renaud-Young Margaret, Gawron Erin, Luong Samantha, Creager Stephen, Birss Viola I. Enhanced Signal Amplification in a Toll-like Receptor-4 Biosensor Utilizing Ferrocene-Terminated Mixed Monolayers.. ACS sensors. 2018. DOI: 10.1021/acssensors.8b01069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.