MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2026.107995

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2026

Contralateral Suppression Index as a Surrogate Marker for Aldosterone Lateralization in Simulated Incomplete Adrenal Vein Sampling.

Basson Derik J, Páez-Carpio Alfredo, Kalu Amos, Mughli Rawan Abu, Du Plessis Jacques, David Elizabeth, Pugash Robyn, Maroun Gilbert

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the contralateral suppression index (CSI) as a diagnostic tool for predicting aldosterone lateralization under simulated incomplete adrenal vein sampling (AVS) and to assess the impact of adrenal nodules and age on its performance.

MATERIALS AND

METHODS

This study retrospectively reviewed consecutive patients who underwent AVS for primary aldosteronism between January 1, 2016, and June 30, 2024. A total of 362 patients were analyzed. Bilaterally selective studies were reanalyzed by masking 1 adrenal side to simulate incomplete sampling. CSI was calculated from the available adrenal vein and inferior vena cava samples and tested across 3 thresholds (≥1.0, ≥0.5, and ≥0.2) using lateralization index (LI) ≥4.0 as the reference. Performance metrics included positive predictive value (PPV), sensitivity, and specificity, overall and stratified by adrenal nodules and age (<35 vs ≥35 years).

RESULTS

Mean CSI was 0.33 in lateralized cases (LI ≥ 4.0) and 3.16 in nonlateralized cases (P < .001). Without a concordant nodule, CSI ≤1 supported lateralization (PPV, 70%; sensitivity, 88%; specificity, 94%); stricter thresholds increased certainty, with CSI ≤0.5 yielding a PPV of 98% and specificity of 99% (sensitivity, 61%) and CSI ≤0.2 achieving a PPV and specificity of 100% (sensitivity, 28%). With a concordant nodule, PPVs were 94%, 99%, and 100% at CSIs ≤1, ≤0.5, and ≤0.2, respectively, with sensitivity of 98%-64% . Results were consistent across age groups.

CONCLUSIONS

CSI reliably predicted aldosterone lateralization under simulated incomplete AVS. Thresholds of ≤0.5 and ≤0.2 provided confirmatory accuracy, particularly when combined with concordant imaging.

Для цитирования: Basson Derik J, Páez-Carpio Alfredo, Kalu Amos, Mughli Rawan Abu, Du Plessis Jacques, David Elizabeth, Pugash Robyn, Maroun Gilbert. Contralateral Suppression Index as a Surrogate Marker for Aldosterone Lateralization in Simulated Incomplete Adrenal Vein Sampling.. Journal of vascular and interventional radiology : JVIR. 2026. DOI: 10.1016/j.jvir.2026.107995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.