MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0194599821989608

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2021

Application of a Computer Vision Tool for Automated Glottic Tracking to Vocal Fold Paralysis Patients.

Wang Tiffany V, Adamian Nat, Song Phillip C, Franco Ramon A, Huston Molly N, Jowett Nate, Naunheim Matthew R

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

(1) Demonstrate true vocal fold (TVF) tracking software (AGATI [Automated Glottic Action Tracking by artificial Intelligence]) as a quantitative assessment of unilateral vocal fold paralysis (UVFP) in a large patient cohort. (2) Correlate patient-reported metrics with AGATI measurements of TVF anterior glottic angles, before and after procedural intervention.

STUDY

DESIGN

Retrospective cohort study.

SETTING

Academic medical center.

METHODS

AGATI was used to analyze videolaryngoscopy from healthy adults (n = 72) and patients with UVFP (n = 70). Minimum, 3rd percentile, 97th percentile, and maximum anterior glottic angles (AGAs) were computed for each patient. In patients with UVFP, patient-reported outcomes (Voice Handicap Index 10, Dyspnea Index, and Eating Assessment Tool 10) were assessed, before and after procedural intervention (injection or medialization laryngoplasty). A receiver operating characteristic curve for the logistic fit of paralysis vs control group was used to determine AGA cutoff values for defining UVFP.

RESULTS

Mean (SD) 3rd percentile AGA (in degrees) was 2.67 (3.21) in control and 5.64 (5.42) in patients with UVFP (P < .001); mean (SD) 97th percentile AGA was 57.08 (11.14) in control and 42.59 (12.37) in patients with UVFP (P < .001). For patients with UVFP who underwent procedural intervention, the mean 97th percentile AGA decreased by 5 degrees from pre- to postprocedure (P = .026). The difference between the 97th and 3rd percentile AGA predicted UVFP with 77% sensitivity and 92% specificity (P < .0001). There was no correlation between AGA measurements and patient-reported outcome scores.

CONCLUSIONS

AGATI demonstrated a difference in AGA measurements between paralysis and control patients. AGATI can predict UVFP with 77% sensitivity and 92% specificity.

Для цитирования: Wang Tiffany V, Adamian Nat, Song Phillip C, Franco Ramon A, Huston Molly N, Jowett Nate, Naunheim Matthew R. Application of a Computer Vision Tool for Automated Glottic Tracking to Vocal Fold Paralysis Patients.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2021. DOI: 10.1177/0194599821989608.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.