MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.70488

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026

Feasibility and Safety of the ETcath200 Robotic PCI System for Complex Coronary Lesions: A Prospective Single-Center Study.

Yang Jing, Fang Yuqi, Yan Yizhu, Liu Zijing, Xie Jing, Zhang Ge, Zhang Zhicheng, Sun Tienan, Zhai Guangyao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

International robotic-assisted PCI platforms such as CorPath 200 and CorPath GRX have demonstrated procedural safety and efficacy but are limited by the absence of real-time tactile feedback and cumbersome device exchange. The ETcath200, the first domestically developed robotic PCI system in China, introduces guidewire force-sensing to provide real-time visual resistance feedback that partially compensates for the lack of direct tactile sensation, along with streamlined device exchange and an intuitive joystick-roller interface.

AIMS: This study aimed to evaluate the feasibility, safety, and procedural performance of the ETcath200 system in patients with complex coronary lesions.

METHODS

In this prospective, single-center, single-arm trial, 20 patients with AHA/ACC type B2 or C complex coronary lesions underwent PCI using the ETcath200 system. Technical success was defined as full robotic completion without any unplanned manual input (including partial manual assistance or manual conversion); clinical success as residual stenosis < 30% with TIMI 3 flow and no in-hospital major adverse cardiac events (MACE). Patients were followed for 30 days.

RESULTS

All 20 patients (mean age 63.2 ± 12.0 years; 80% male) had unstable angina and complex coronary anatomy (79.2% type C lesions; 50% bifurcation, 65% diffuse). Most procedures were performed via radial access (80%), and the majority utilized drug-eluting stents (65%). Technical success was achieved in 16 cases (80%), while four cases (20%) required manual conversion due to severe tortuosity or calcification (n = 3) or guidewire-induced dissection (n = 1; managed successfully). All patients achieved clinical success; no device failures, MACE, or serious adverse events occurred at 30 days. Mean procedure duration was 61.0 ± 23.3 min; radiation dose was 0.07 ± 0.04 mSv.

CONCLUSIONS

The ETcath200 robotic PCI system demonstrated feasibility, safety, and reliable performance in complex coronary lesions, achieving high clinical success and excellent short-term outcomes. Manual conversion was required only in anatomically challenging cases. These data support further multicenter evaluation of ETcath200 in complex coronary interventions.

Для цитирования: Yang Jing, Fang Yuqi, Yan Yizhu, Liu Zijing, Xie Jing, Zhang Ge, Zhang Zhicheng, Sun Tienan, Zhai Guangyao. Feasibility and Safety of the ETcath200 Robotic PCI System for Complex Coronary Lesions: A Prospective Single-Center Study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2026. DOI: 10.1002/ccd.70488.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.