MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2025.12.005

Медицинская библиотека · Journal of cardiology · 2025

Nonstenotic carotid artery plaque in patients with cryptogenic stroke after ICM: A sub-analysis of the LOOK study.

Komatsu Teppei, Katano Takehiro, Suda Satoshi, Iguchi Yasuyuki, Morimoto Masafumi, Tsuboi Yoshifumi, Sonoda Kazutaka, Koga Masatoshi, Ihara Masafumi, Murakami Hidetomo, Yazawa Yukako, Kimura Kazumi

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate whether differences in carotid plaque size between the ipsilateral and contralateral sides of the stroke site influence the detection of atrial fibrillation (AF) after cryptogenic stroke (CS).

METHODS

We analyzed data from the prospective, multicenter LOOK Study, which enrolled patients with CS diagnosed and monitored using an implantable cardiac monitor (ICM). The study included patients with unilateral anterior circulation cerebral infarction, divided by whether AF was detected within 6 months of ICM implantation. Carotid plaque size was compared between the ipsilateral and contralateral sides of the stroke site.

RESULTS

Ninety-seven patients (32 women; median age 70 years; median NIHSS 3) were included; 21 developed AF. Among patients without detected AF, carotid plaques ≥1.4 mm were significantly more frequent on the ipsilateral side compared to the contralateral side (27/76 vs. 18/76, p = 0.022). Conversely, patients with detected AF showed no significant difference in plaque size between ipsilateral and contralateral to the stroke site (1.5 mm vs. 1.7 mm, p = 0.754). For patients with an ipsilateral plaque ≥1.4 mm, an ipsilateral-to-contralateral plaque size ratio of ≥1.2 demonstrated a specificity of 75 % and sensitivity of 63 % for predicting no detected AF (area under the curve = 0.727, 95 % CI 0.543-0.911, p = 0.025).

CONCLUSION

This study demonstrated that carotid plaque distribution patterns differ significantly between CS patients with and without detected AF. An ipsilateral carotid plaque ≥1.4 mm and a size ratio ≥ 1.2 may predict no detected AF, potentially indicating an embolic source other than AF.

Для цитирования: Komatsu Teppei, Katano Takehiro, Suda Satoshi, Iguchi Yasuyuki, Morimoto Masafumi, Tsuboi Yoshifumi, Sonoda Kazutaka, Koga Masatoshi, Ihara Masafumi, Murakami Hidetomo, Yazawa Yukako, Kimura Kazumi. Nonstenotic carotid artery plaque in patients with cryptogenic stroke after ICM: A sub-analysis of the LOOK study.. Journal of cardiology. 2025. DOI: 10.1016/j.jjcc.2025.12.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.